Operating instructions
42D0200
Designer Series Gas Fireplaces
11
Minimum distance between a glass panel and a parallel
wall = 42"
Minimum distance between the edge of a glass panel and
an adjacent wall = 3"
(Maximum length of horizontal venting = 20'. Refer to the
venting section of this manual for specic dimensions.
Figure 7 -
Possible Fireplace Locations
FP2277
A Flat on Wall
B Room Divider
X
X
X
A
B
Y
Y
Z
A
Y
FP2277
locate fireplace
The replace must be secured to the oor and/or to framing
studs as shown in Figure 8. Use two (2) wood screws or
masonry/ concrete screws to secure replace to the oor.
Use four (4) screws to attach replace to framing. The side
brackets are adjustable from 1/2" to 5/8" to accommodate
different thickness of noncombustible material.
FP2278
secure fireplace
Figure 8 -
Secure Fireplace to Floor and Framing Studs
Screws
FP2278
1. Unlatch and remove glass door. Refer to Page 30.
2. Remove three (3) top louvers by pulling rmly.
3. Locate screws on upper frame and remove. (Five (5)
screws on long side and three (3) screws on short
side.) Figure 9
4. Install canopy hood and secure using
screws previously removed.
5. Reinstall louvers and glass door.
FP2918
canopy install
Figure 9 -
Install ALL Canopies
FP2918