Specifications
Equipment details
94
Equipment details
95
15
5. Slide the holding tank into position through
access door (fig. 5).
6. Makesuretheholdingtankissecuredby
the retaining clip. (fig. 6).
7. Open the waterfill door and add 50 ml of
AquaRinse.AquaRinseresultsinabetter
ushandimprovesthehygieneofthe
toilet. Then fill the watertank with fresh
water using a jerrycan or a hose. Tank
capacity is 7 litres (fig. 7).
Operation
8. Turn the bowl in the most comfortable
position (fig. 8).
9. C-200 CW only:Beforeusingthetoiletitis
recommendedtoushsomewaterintothe
bowlbyliftingandpressingdowntheush
handle (fig. 9).
9a. C-200 CWE & CS only:Beforeusingthe
toiletitisrecommendedtoushsome
water into the bowl by pressing and
releasingtheushbutton(g.9a).
10. The toilet may be used with the blade open
or closed. Pull valve handle towards you to
open (fig. 10).
11. C-200 CW only: After use, open valve
blade(ifstillclosed)andush,lifttheush
handle and press it down (fig. 11). After
ushing,closethebladebyturningthe
blade handle.
11a. C-200 CWE & CS only: After use, open
valveblade(ifstillclosed)andush,press
theushbutton(g.11a).
Afterushing,closethebladebyturningthe
blade handle.
The waste holding tank is located underneath
the toilet and is removed for emptying from
the outside of the vehicle through an access
door. A rotating pour out spout, automatic
holding tank vent, air release valve, valve
blade, carrying handles and hand grip are
incorporated in the waste holding tank. A
sliding cover guarantees optimal hygiene.
Emptying the Holding Tank
The holding tank capacity is approx. 17 litres
and the tank should be emptied when the
waste-level indicator lights up. The waste-
level indicator lights up when the holding tank
contains more than 15 litres of waste.
CAUTION: Do not allow the holding tank
to become overfilled. See trouble shooting
section for emergency emptying procedure.
12. Open access door and remove the holding
tank. The holding tank can only be removed
when the valve blade is closed (fig. 12).
13. Carry the holding tank to a normal
household type toilet or other authorised
disposal point. Place the holding tank in
vertical position and rotate pour out spout
upwards (fig. 13).
14.Removethespoutcap.Graspunitby
upper carrying handle nearest to pour
out spout. Place other hand on upper
rear hand grip so that vent button can be
depressed with the thumb while emptying.
Thisensuresasmoothoutowofthetank
contents. (fig. 14).
Note:Onlydepresstheventbuttonwhen
pour out spout is pointed downwards.
Rinsetheholdingtankwithcleanwater.For
preparing for use again, see steps 1 to 7.
Cleaning and maintenance
The lipseal and the seal of the automatic vent
are made of rubber and therefore these parts
need regular maintenance (depending on
frequency of use, once or twice a month).
THETFORD CASSETTE TOILET
Cassette C-200 CW and C-200 CWE &
C-200CS
The toilet section of the C-200 includes a
rotatable bowl, removable seat and cover,
aconsolewithaushhandle/ushbuttons,
abuiltinush-watertankandawastelevel
warning indicator. The valve blade handle is
located underneath the bowl.
Preparing for Use
1. Open access door pull retaining clip
upwards (fig. 1).
2. Removeholdingtankbypullingstraightout.
When holding tank hits the stop, tilt front
end downwards slightly and remove (fig. 2).
3. Position tank vertically and swivel pour out
spout upwards (fig. 3).
4. Removethecapofthepouroutspout.Add
requiredquantityoftoiletuidthroughpour-
out spout then add approx. 2 litres of water
through the spout to cover holding tank
bottom.Replacecapandreturnpourout
spout to its original stored position (fig. 4).
Note:Warmerweatherorlongerintervals
between emptying the waste tank may require
additionaltoiletuid.UseonlyThetfordtoilet
uidtoachievethebestresults.
Caution: Never add toilet fluid directly into
toilet bowl.
1
2
3
4
5
6
7
8
10
11
9
9a
13
14
11a
12