Unusual noises
FAULT POSSIBLE CAUSE REMEDY
Loud humming A component of the refrigerant circuit cannot move freely
(touching the wall)
Foreign body jammed between the cooling unit and the wall
Fan noise
Bendthecomponentcarefullyaway
from the obstruction
Removetheforeignbody
Compressor is not running (connected to AC supply)
FAULT POSSIBLE CAUSE REMEDY
Novoltage Interruption in the supply cable
Mainswitchfaulty(ifinstalled)
Additional supply line fuse has blown (if installed)
Establish a connection
Replacethemainswitch
Replacethesupplylinefuse
Voltageispresentbutthe
compressor doesn’t run
Ambient temperature too high
Insufficient ventilation and/or air supply
Condenser is dirty
Movetherefrigeratortoanotherlocation
Clean the condenser
Electric circuit between the pins in
the compressor interrupted
Defective compressor Replacethecompressor
Poor cooling, interior temperature increases
Compressor runs for a long time/
continuously
Ambient temperature too high
Insufficient ventilation and/or air supply
Condenser is dirty
Faulty fan
Movetherefrigeratortoanotherlocation
Clean the condenser
Replacethefan
Compressor runs intermittently Batterycapacityexhausted Charge the battery