Specifications

Equipment details
60
Equipment details
61
is destined. These hoses must be checked
regularly for brittleness. Winter-proof special
hoses must always be used if the equipment is
operated during the winter.
If the pressure regulator is exposed to weather
conditions – especially on trucks – always make
sure to protect the regulator using the Truma
protective cover (standard accessory in truck
attachment kit).
Technical data
determinedinaccordancewithEN624or
Truma test conditions
Type of gas:
Liquid gas (propane/butane)
Operating pressure:
30 mbar (see data plate)
Rated thermal output
High setting: 2400 W
Low setting: 1200 W
Gas consumption
High setting: 200 g/h
Low setting: 100 g/h
Air flow rate
High setting: approx. 78 m3/h
Low setting: approx. 49 m3/h
Current input at 12 V
High setting: 1.1 A
Low setting: 0.6 A
Current input at 24 V
High setting: 0.7 A
Low setting: 0.4 A
Standby:
0.01 A
Weight:
approx. 4.7 kg
Declaration of conformity:
The Trumatic E 2400 has been tested by the
DVGWandcomplieswiththegasequipment
directive (90/396/EEC) and the other applicable
EC directives. The following CE Product Ident.
No.isavailableforEUcountries:
CE-0085AP0008.
The heater complies with heater directive
2001/56/EC and supplements 2004/78/EC
and 2006/119/EC and bears the type approval
number: e1 00 0144.
The heater complies with vehicle engine
interference suppression directive 72/245/EEC
with supplements 2004/104/EC and 2005/83/
EC, and bears type approval number:
e1 03 2605.
TheheatercomplieswithEMCdirective
89/336/EEC and low voltage directive
72/23/EEC.
eneral safety notes
If the gas system is leaking or if there is a smell
of gas:
•extinguishallnakedames
•donotsmoke
•switchofftheappliances
•shutoffthegascylinder
•openwindowsanddoor
•donotactuateanyelectricalswitches
•havetheentiresystemcheckedbyanexpert!
Repairs may only be carried out by
an expert!
A new O-ring must always be installed after
dismantling the exhaust duct!
1. Any alteration to the appliance (including
exhaust duct and cowl) or the use of spare
parts and accessories which are important
to the function of the heater and which are
not original Truma parts, as well as the non-
observance of the installation and operating
instructions, will lead to the cancelling of
the guarantee and exclusion of liability
claims. It also becomes illegal to use the
appliance, and in some countries this even
makes it illegal to use the vehicle.
2. The operating pressure for the gas supply
is 30 mbar and must correspond to the
operating pressure of the appliance (see
data plate).
3. Liquid gas systems must comply with the
technical and administrative regulations of
therespectivecountryofuse(e.g.EN1949
forvehiclesorENISO10239forboatsin
Europe).Nationaldirectivesandregulations
(e.g.DVGWworksheetG607forvehicles
and G 608 for boats in Germany) must be
complied with.
For vehicles for commercial use, the relevant
accident prevention regulations issued by the
professional associations are to be respected
(BGVD34).
The inspection of the gas system is to be
repeated every two years by an approved liquid
gasspecialist(DVFG,TÜV,DEKRA).Thisisto
be confirmed on the corresponding inspection
certicate(G607,G608,orBGG935).
The keeper of the vehicle is responsible for
arranging the inspection.
Pressure regulating equipment and hoses must
be replaced with new ones no more than 10
years after the date of manufacture (every 8
years if used commercially).
This is the responsibility of the operator.
4. Liquid gas equipment must not be used
when refuelling, in multi-storey car parks, in
garages or on ferries.
5. During the initial operation of a brand new
appliance (or after it has not been used for
some time), a slight amount of fumes and
smell may be noticed for a short while. This
can be remedied by running the heater at
maximum output and ensuring adequate
room ventilation.
6. If the burner makes an un-usual noise
oriftheameliftsoff,itislikelythatthe
regulator is faulty and it is essential to have
it checked.
7. Items sensitive to heat (e.g. spray cans)
must not be stored in the installation area,
since excess temperatures may under
certain circumstances be incurred there.
8. Only pressure control equipment that
complieswithEN12864(invehicles)andEN
ISO 10239 (for boats) with a fixed delivery
pressure of 30 mbar must be used for the
gassystem.Theowrateofthepressure
control device must correspond to at least
the maximum consumption of all devices
installed by the system manufacturer.
For vehicles we recommend the Truma
SecuMotiongaspressureregulatorandthe
Truma DuoComfort automatic changeover valve
for the two-cylinder system.
At temperatures of around 0°C or less the
gas pressure regulator and the changeover
valve must be operated using the EisEx
de-icing system.
Controller connecting hoses that meet national
regulations must always be used in the
respective country for which the equipment