User manual

1
2
3
LC7TT novo
11
Validation of force
Start Monark Test Software (it is available for free
download from our web site: www.monarkexercise.
se) and select a test programme from the menu "Test".
In the dialogue box that opens is a box showing the
braking force in Newton, see Fig: Force and HR
display. You do not have to press "Start" (1) to get
the heart rate showed (2), but you must press "Start"
to show the force (3).
1. With the pendulum pointer at 0, the display should
show "00N"
2. Move the pendulum pointer to 4 kp and the display
should show "39N"
If the braking force is not displayed correctly, an
calibration of the pendulum must be done. See section
"Calibration".
NOTE!
After this verification, the brake belt will be loose.
This means that it will take some seconds before the
regulating device has tensed the brake belt to normal
again after you have started pedalling. If it then heavy
to pedal, add force on the pedals and the bike will
drop on the work load until it is possible to pedal
around.
Fig: Force and HR display
1) Start
2) Heart rate display
3) Force in PC software (manual test)