Troubleshooting guide
- 0 Terminal/PC
-1-3 see manual
- (0) _
1
2 3
4
6
7
5
Monark 839 E
8
First check the brake belt tension. If the belt is too
tight loosen it a little by moving the pendulum to
about 4 kp and hold it there for a few seconds. Then
the force-adjusting servo will loosen the belt tension.
To be sure that pendulum positions are correct, do a
calibration. See ”Electronic calibration”.
Press the switch to turn off the power, see 1. fig:
Connections. Disconnect the cable from any
connected device.
Adjust the scale mechanically so that 0-index on 2.
the scale and the mark on the pendulum are in
line.
Move the pendulum to 6 kp and hold it there.3.
Turn on the power again. The green LED (3) lights 4.
when power is connected to the bike.
Hold the pendulum at 6 kp until two beeps are 5.
heard.
Move the pendulum to: 6.
0 = mode for use with PC or hand unit.
1 = mode for Siemens Megacart ECG.
2 = mode for other ECG devices, alt 1.
3 = mode for other ECG devices, alt 2.
Hold the selected position until two beeps are 7.
heard. Then release the pendulum to 0. The system
will now restart in the seleted mode.
Alt. 1: ECG, Ergoline compatible command set,
requested load value.
Alt. 2: ECG, Ergoline compatible command set, cur-
rent load value.
What command type is set?
When the power is turned on a beep is heard and
depending on the beeps number you can decide which
command type is set.
Commando type 0: One long beep. •
Commando type 1: A long beep followed by a •
short beep.
Commando type 2: A long beep followed by two •
short beeps.
Commando type 3: A long beep followed by three •
short beeps.
Connection to controller
Fig: Connection
1) Printer connection
2) Power switch
3) Power connection
4) LED
5) Chassis ground
6) Terminal/PC (serial)
7) Analogue connection
Setting of terminal
When using a terminal (Art. No: 9339-51) do as
follows:
Connect the terminal to the bike using the 1.
enclosed cable.
Connect power to the bike. 2.
When the main menu is displayed on the LCD-3.
screen press ‘99’ and the hidden service menu
appears.
Press ‘6’, ”Settings”.4.
Press ‘ENTER’ (normally 13 times) until the 5.
display ”Command type” appears.
a) Press ‘1’ and ‘ENTER’ if the bike is
connected to a Siemens Megacart ECG device.
b) Press ‘2’ and ‘ENTER’ if the bike is
connected to other ECG device with an Ergoline
protocol for communication, alt. 1.
c) Press ‘3’ and ‘ENTER’ if the bike is
connected to other ECG device with an Ergoline
protocol for communication, alt. 2.
d) Press ‘0’ if the bike is connected to a terminal
or PC.
6. After that press ‘0’ twice to go back to main
menu.
Setting of command type (PC or ECG device)
From software version R15