Setup guide
40
SIT & REACH (Range of Motion)
Range of Motion handle is not retracting
1. If the ROM handle is not retracting, the internal mechanism needs to be repaired by
Polar/HealthFirst service personnel.
2. Remove the ROM unit from the Sit & Reach station using a 5/32” Allen wrench
provided with your system.
3. Remove the only the 2 silver colored upper screws, DO NOT remove the smaller
lower black colored screws.
4. Unplug the ROM cable from the TriFIT 700iu box.
5. Remove the ROM unit.
6. Contact Tech Support for information on repairing your Range of Motion.
Range of Motion is inconsistent
1. Re-calibrate ROM (Defaults/Calibration) according to the instructions on the screen.
*It is much easier and more accurate to calibrate the ROM with two people.
2. Enter into a client test and perform another Sit and Reach test.
3. When the screen prompts to “Zero the System”, pull the handle out exactly 12” from
the foot plate and press the Enter key.
4. Return the handle slowly to the foot plate and allow the TriFIT to take the reading.
5. The measurement should be within ½ “ of 12”.
6. If the measurement is not within ½”, re-calibrate and repeat.
7. If still not within ½”, call the Polar/HealthFirst Corporation Technical Support Line
(505-344-9679).
If an error message appears on the screen during normal operation, print the error and fax to
Polar/HealthFirst Corporation Technical Support at 505/344-1200. To print a fax technical
request form from TriFIT, go to Help and Technical Support. Complete the form and click
print. You can then fax this form for quicker response to your question.
For additional technical support, check on the web at
www.polarusa.com