Instruction Manual
3
NOTE: The Full scale output settings must have been specified when
ordered or may be user programmed using the User
Programming Cable.
2.2.1 Current Output Option
The current output is 4 to 20 mA. This output is a current source
and has a 10 Vdc internal compliance voltage. The maximum load
that may be connected is 450 ohms.
Typical connections are as follows: (Shown
right)
Connections for current out are to the terminals
marked ANALOG OUT. Connect the Positive
side of the load to the terminal marked + and the
other side of the load to the terminal marked -.
2.2.2 Voltage Output Option
The voltage output is 0 to 5 Vdc.
Connections for voltage out are to the terminals
marked ANALOG OUT. Connect the Positive
side of the load to the terminal marked + and the
negative or common side of the load to the terminal marked -.
2.3 Sensor Input
The SENSOR INPUT is the input terminal used to connect an external
sensor or trigger source. There is a voltage output that may be used to
power an external sensor (5 or 12 Vdc – user selectable at 75mA max).
The system supports two wire inputs (Signal and Common) or three
wire sensors (Supply, Signal and Common). Three wire sensors can be
open collector types – NPN or PNP, TTL output or –ve output types.
8
5.0 SPECIFICATIONS
Input Range: 0.1 to 10 KHz, 5 to 600,000 RPM
Accuracy: 0.005%
mA Option: 4 to 20 mA out, 16 bit resolution 10Vdc compliance
voltage. Zero and full scale settings as specified when
ordered or user programmable using USB Programming
Cable and PM Remote Software
Vdc Option: 0 to 5 Vdc out, 5 mA 16 bit resolution. Zero and full
scale settings as specified when ordered or programmable
using USB Programming Cable and PM Remote Software
Resolution: 76 microvolts or 30.5 micro amps
Dimensions: L x W x H = 80 x 40 x 28 mm (3.2 x 1.6 x 1.2 inches)
excluding the mounting wings
Power Supply: 12 to 24Vdc +5% @ 150mA max
Input: TTL input or +3 Vac to +12 Vac
Sensor Supply: 5Vdc or 10 Vdc at 75 mA – User selectable
This product is CE certified and ROHS compatible.
Manufactured in an ISO9001 facility.
For troubleshooting information and technical support visit
www.monarchinstrument.com.