Owner`s manual

WATER SYSTEMS — 6
132
2008 KNIGHT
To Empty the Black Tank (Solid Waste):
Close the black tank (solid waste) and
grey tank (liquid waste) valves.
Remove the terminal drain outlet cap.
Secure the exible sewer hose from
the Sani-Con macerator pump to the
termination drain outlet by aligning
the sewer hose coupler tangs with
the terminal tabs. Twist the coupler
clockwise to lock it to the terminal outlet.
Remove the drip cap at 1 ½” end of
discharge nozzle (see illustration).
WARNING
Be sure to remove the drip cap from
the Sani-Con hose end (see illustration).
Failure to do so will result in damage to
the Sani-Con system.
CAUTION
If the pump is activated while the drip
cap is on the hose end, switch the pump
off (use the Sani-Con On/Off switch) and
wait at least
30 seconds to
allow pressure
to dissipate
before
removing the
drip cap.
Periodically tighten all hose clamps.
Install discharge nozzle to the sewer
connection (dump station). Adapters
allow the discharge nozzle to be adapted
from 3” to 4” threaded or non-threaded
sewer connection. Ensure the discharge
nozzle is installed correctly prior to
operation.
Open the solid waste (black tank) valve
by pulling outward.
Turn on the waste pump using the Sani-
Con switch located on Water Service
Center panel.
Push the test switch on the monitor panel
to read tank level. Allow the black tank
to empty.
When the black tank is empty, turn off
the Sani-Con pump and leave the black
tank valve open.
Store sewer hose and Sani-Con discharge
nozzle for travel. Secure termination cap
(required by law in some states).
If desired, add chemicals to the holding
tanks to control odor. Follow the
chemical manufacturers directions.
To Empty the Grey Tank (Liquid Waste):
Secure the exible sewer hose from
the Sani-Con macerator pump to the
termination drain outlet.
Remove the drip cap at 1 ½” end of
discharge nozzle (see illustration).
Periodically tighten all hose clamps.
Install discharge nozzle to the sewer
connection (dump ststion). Adapters
allow the discharge nozzle to be adapted
from 3” to 4” threaded or non-threaded
sewer connection. Ensure the discharge
nozzle is installed correctly prior to
operation.
If applicable, close the black tank (solid
waste water) valve.
Open the grey tank valve.
Turn on the Sani-Con pump. Allow the
grey tank to empty.
Push the test switch on the monitor panel
to read tank levels.
If applicable, the black tank (solid waste)
can be emptied at this time.
Turn the Sani-Con pump off.
Close the grey tank drain valve and, if
applicable, the black tank valve.
Store sewer hose and Sani-Con discharge
nozzle for travel. Secure termination cap
(required by law in some states).
If desired, add chemicals to the holding
tanks to control odor. Follow the
chemical manufacturers directions.
Using Tank Flush:
WARNING
Never operate the flush system
unattended. Flooding may occur. Use the
tank flush system each time the holding
tanks are cycled. Failure to routinely use
the flush system will result in a clogged
spray nozzle. Turn off the water supply
when finished flushing the tank.
Secure the exible sewer hose from
the Sani-Con macerator pump to the
termination drain outlet.
Remove the drip cap at 1 ½” end of
discharge nozzle (see illustration).
Periodically tighten all hose clamps.
Install discharge nozzle to the sewer
connection (dump station).
040623b
040516t