Specifications

4/66
Schneider Electric
4
Presentation
4
Quantum automation platform 4
Momentum Modbus Plus Communication Adapters
Modbus Plus Communication Adapters for the Momentum I/O product line can be
plugged into any Momentum I/O base to create a functional I/O unit on the Modbus
Plus bus, and to provide a direct connection to the Modbus Plus Network for the full
family of Momentum I/O modules. This connectivity enables communications with all
of the Modbus Plus compatible control products - including programmable
controllers, industrial computers, operator control stations, drive systems, and other
controls - to provide a flexible, cost-effective solution for distributing I/O modules
throughout a large area. To expand the capabilities of the Modbus Plus Network for
distributed I/O applications, the communication adapters have been designed to
permit up to 64 Momentum I/O modules to be connected to the network without the
need for signal repeaters.
Each Momentum I/O module is an individual node on the Modbus Plus network with its
address user-selected on the dual rotary switch on the front of the communication
adapter. The Momentum I/O modules can be configured for the network, and
assigned program reference numbers, by using either the Peer Cop function or the
MSTR function block instruction in the programmable controller or the Modbus Plus
configuration in an industrial computer.
There are four types of Communication Adapters available :
b 170 PNT 110 20, Single Port, IEC Data Format.
b 170 PNT 160 20, Redundant Port, IEC Data Format.
b 170 NEF 110 21, Single Port, 984 Data Format.
b 170 NEF 160 21, Redundant Port, 984 Data Format.
This version of the Momentum Modbus Plus Communication Adapter communicates
I/O data to the programmable controller in the IEC data format, which has bit
numbering 0 through 15, right to left, within the data word (i.e., input or output number
1 is bit number 0).
This version of the Momentum Modbus Plus Communication Adapter communicates
I/O data to the programmable controller in the traditional 984 data format, which has
bit numbering 1 through 16, left to right, within the register (i.e., input or output number
1 is bit number 1).
Since Modbus Plus is supported by the Quantum and 984 controller families,
Momentum I/O can be added to existing control systems where additional I/O
capacity or a distributed I/O sub-network is needed, because of requirements for the
control system. The figures below illustrate typical control systems using Momentum
I/O modules on the Modbus Plus network with programmable controllers and
industrial computer systems.
Presentation
IEC Data Format
984 Data Format
C
haracteristics :
p
age 4/67
References :
page 4/69