Specifications

25
6.4. Variables values setting and allowed range
Heater preset time HTP: 1 to 120 minutes; whole positive numbers only; 999 = switch ON unlimited
Alarm signal pulse length, alarm status hold ON :
AP: 0.1 to 9.9 seconds
APH: 1 to 999 seconds; whole positive numbers only
Car battery voltage, time constant for voltage change stability:
CBV: 5.0 to 40.0 Volts
VS: 1 to 999 seconds; whole positive numbers only
Periodical connectivity test can accept following values:
PTD: 0 to 99 days, only positive numbers are accepted.
PTH: 0 to 24 hours, only positive numbers are accepted.
PTM: 0 to 60 minutes, only positive numbers are accepted.
Temperature limit values, time constant for temperature change stability
UST, UST1, UST2: - 40.0 to +125.0 °C (- 40.0 to +257.0 °F when che ck box No. 19 is activated)
for UST1 and UST2 must be: UST1 > UST2
TS, TS1: 0 to 999 seconds; positive numbers only
Voice messages language LANG: 1 to 14; whole positive numbers only
CommandCall CC2 uses internal format of decimal numbers with decimal point and sent SMS
reports also contain decimal point as separator of whole and decimal part of the numbers.
However, PC Setup accepts both comma and point as decimal part separator (for accepting
regional settings of various PC users).
6.5. PC Setup values handling
Print: prints out the content of PC Setup screens on 3 separate pages on connected printer
Request: reads out the memory of the CommandCall control unit and displays the values on the screen
Apply: writes PC setup screen actual values into CommandCall control unit memory