CONDITIONS:
After crimping, the conductor profiles should measure the following.
Conductor Crimp Insulation Crimp
Wire Size
Height (Ref.) Width (Ref.) Height (Ref.) Width (Ref.)
Pull Force
Minimum
Profile
Terminal
Series No
AWG mm
2
mm In. mm In. mm In. mm In. N Lb. 20 22-24 26-30
20 0.50 0.89-0.99 .035-.040 1.40 .055 1.70 .067 1.83 .072 57.8 13.00 X
22 0.35 0.83-0.93 .033-.037 1.40 .055 1.58 .062 1.72 .068 35.6 8.00 X
24 0.20 0.83-0.93 .033-.037 1.40 .055 1.58 .062 1.72 .068 22.2 5.00 X
26 0.12 0.70-0.80 .028-.031 1.10 .043 1.38 .054 1.41 .056 13.3 3.00 X
28 0.08 0.70-0.80 .028-.031 1.10 .043 1.38 .054 1.40 .055 8.9 2.00 X
43030
30 0.05 0.70-0.80 .028-.031 1.10 .043 1.38 .054 1.40 .055 6.7 1.50 X
20 0.50 0.89-0.99 .035-.040 1.40 .055 1.70 .067 1.83 .072 57.8 13.00 X
22 0.35 0.83-0.93 .033-.037 1.40 .055 1.58 .062 1.72 .068 35.6 8.00 X
24 0.20 0.83-0.93 .033-.037 1.40 .055 1.58 .062 1.72 .068 22.2 5.00 X
26 0.12 0.70-0.80 .028-.031 1.10 .043 1.38 .054 1.41 .056 13.3 3.00 X
28 0.08 0.70-0.80 .028-.031 1.10 .043 1.38 .054 1.40 .055 8.9 2.00 X
43031
30 0.05 0.70-0.80 .028-.031 1.10 .043 1.38 .054 1.40 .055 6.7 1.50 X
OPERATION
CAUTION: Install only Molex terminals listed above with this tool. Do not crimp hardened objects as damage can
occur to the tool or die.
Open the tool by squeezing the handles
together. At the end of the closing stroke,
the ratchet mechanism will release the
handles and the hand tool will spring open.
See Figure 1.
Crimping Terminals
1. Select the desired terminal listed in the
preceding charts.
2. Make sure the center of the locator is
in the down position. With the locator
attached, push the locator button on
the back of the hand tool to bring the
locator forward through the tooling.
See Figure 2.
3. While holding the locator button in, load the terminal into the proper nest opening in the locator based on the
wire gauge or terminal type markings on the hand tooling. See Figure 3.
SQUEEZE
HANDLES
TOGETHER
HANDLE WILL
SPRING OPEN
Figure 1
LOCATOR
IN DOWN
POSTION
PUSH ON THE
LOCATOR BUTTON
Figure 2