Datasheet

63813-1500 Extractor Tool
Order No: ATS-638131500 Release Date: 04-02-03 UNCONTROLLED COPY Page 4 of 4
Revision: H Revision Date: 07-16-09
Figure
5
EXTRACTOR TOOL
HOUSING
WIRE
PUSHED
DOWN
AND PULL THRU
TERMINAL
PUSH IN
TERMINAL
AND WIRE
TERMINAL
EXTRACTOR TOOL
2. The Latch on the housing will open and then release the terminal. Pull the crimped terminal out by the wire
in the direction shown. See Figure 3 and 4.
For 34564 Terminal Series:
1. Push the terminal and wire forward in the arrow direction before using the Extractor Tool.
2. Insert the tip of the Extractor tool below the seal and terminal into the hole of the connector housing.
3. Gently push the tool under the terminal until the wings of the terminal lift up and out of the slot.
4. Using an eraser end of a pencil push down on the top of the terminal.
5. Pull the terminal and wire out of the hole. See Figure 5.
Molex does not offer repair parts for this tool due to the inexpensive nature of the tool
Americas Headquarters
Lisle, Illinois 60532 U.S.A.
1-800-78MOLEX
amerinfo@molex.com
Far East North Headquarters
Yamato, Kanagawa, Japan
81-462-65-2324
feninfo@molex.com
Far East South Headquarters
Jurong, Singapore
65-6-268-6868
fesinfo@molex.com
European Headquarters
Munich, Germany
49-89-413092-0
eurinfo@molex.com
Corporate Headquarters
2222 Wellington Ct.
Lisle, IL 60532 U.S.A.
630-969-4550
Fax: 630-969-1352
Visit our Web site at http://www.molex.com
EXTRACTOR
TOOL
WIRE
HOUSING
Figure
4
EXTRACTOR TOOL
TERMINAL