Datasheet

63813-1500 Extractor Tool
Order No: ATS-638131500 Release Date: 04-02-03 UNCONTROLLED COPY Page 3 of 4
Revision: H Revision Date: 07-16-09
LOCKING TAB
OF TERMINAL
WIRE
Figure
2
EXTRACTOR
TOOL
LOCKING TAB
PUSHED DOWN
TERMINAL
HOUSING
EXTRACTOR
TOOL
Figure
3
EXTRACTOR
TOOL
TERMINAL
HOUSING
POCKET
180°
°°
°
Disoriented
Terminal
90°
°°
°
Disoriented
Terminal
TERMINAL INSTALLATION
Terminal Orientation Feature
This is the Terminal orientation at the matte seal
grommet cap.
OPERATION:
For 501647, 501648, and 5103 Terminal Series:
Individual terminals may be extracted from the housing using this Tool.
1. Push the terminal and the wire forward in the arrow direction before using this Tool. Insert the Tool into the
slot above the locking tang of the terminal. Push the tool down until the locking tang is even with the rest of
the terminal. This will free the terminal from the housing.
2. Holding the wire and the tool together, pull the wire back through the connector slot in the arrow direction
as shown in Figure 2.
For 59323 Terminal Series:
Individual terminals may be extracted from the housing using this
Tool.
1. Insert the tip of the Extractor Tool into the end of the pocket of
the housing. Push the tool down until it stops.