Datasheet
Hand Crimp Tool for MX150L™ Crimp Terminals
Doc No: ATS-638114400 Release Date: 04-05-04 UNCONTROLLED COPY Page 2 of 5
Revision: D Revision Date: 07-25-08
CONDITIONS:
After crimping, the crimp profiles should measure the following (see notes on page 5).
Bell mouth Conductor Brush Bend up Bend Down Twist Roll Terminal
Series No.
mm In. mm In. Degree Degree
19417 0.25-1.25 .010-.049 0.15-0.65 .006-.026 5 5 4 8
19420 0.25-1.25 .010-.049 0.15-0.65 .006-.026 5 5 4 8
Conductor Crimp Ref. Insulation Crimp Ref.
Wire Size
Height Width Height Maximum Width
Pull Force
Minimum
Profile
AWG
Terminal
Series No.
AWG
mm
2
mm In. mm
In.
mm In. mm In. N Lb. 18-22
14-16
14 2.00
1.45-1.55
.057-061
2.50
.098
3.50 .138 4.30 .169
222.6
50.00
X
16 1.27
1.45-1.55
.057-061
2.50
.098
3.50 .138 4.30 .169
133.5
30.00
X
18 0.83
1.10-1.20
.043-.047
2.00
.079
3.50 .138 3.40 .134
89.0
20.00
X
20 0.83
1.10-1.20
.043-.047
2.00
.079
3.50 .138 3.40 .134
57.9
13.00
X
19417
22 0.83
1.10-1.20
.043-.047
2.00
.079
3.50 .138 3.40 .134
35.6
8.00 X
14 2.00
1.45-1.55
.057-061
2.50
.098
3.50 .138 4.30 .169
222.6
50.00
X
16 1.27
1.45-1.55
.057-061
2.50
.098
3.50 .138 4.30 .169
133.5
30.00
X
18 0.83
1.10-1.20
.043-.047
2.00
.079
3.50 .138 3.40 .134
89.0
20.00
X
20 0.58
1.10-1.20
.043-.047
2.00
.079
3.50 .138 3.40 .134
57.9
13.00
X
19420
22 0.36
1.10-1.20
.043-.047
2.00
.079
3.50 .138 3.40 .134
35.6
8.00 X
OPERATION
Open the tool by squeezing the handles together, at the end of the
closing stroke, the ratchet mechanism will release the handles, and
the hand tool will spring open.
Crimping Terminals
1. Select the proper locator on the locator assembly for the proper
terminal. The female locator is gray and is marked with an “F”.
The male locator is black and is marked with an “M”.
2. To position the desired locator, pull up on the knurled pin and turn
180° till the locator fits snuggly in the slot. See Figure 3,
Assembly Drawing.
3. Lift the wire stop blade up.
4. Insert the terminal fully into the correct die profile and the locator slot until the terminal is fully seated and
stops.
5. Bring down the wire stop blade. Make sure the wire stop blade is fully seated on the terminal behind the
conductor grip section.
6. Slide the pre-stripped wire into the terminal; make sure to aim the wire brush towards the tip point on the
wire stop blade. See Figure 1. Align the wire so that it is parallel and sitting into the terminal. Maintain a
light and constant pressure on the wire that is seated in the terminal at all times. (Do not let go of the
wire.) Be sure to hold the wire and terminal in place until the terminal is fully crimped. See Figure 2.
7. Close the tool until the ratchet releases.
8. Lift the wire stop blade up.
TERMINAL
PRE
-
STRIPPED
WIRE
LOCATOR
Figure 1
WIRE STOP
BLADE