Maintaining the Half-mask
The maintenance intervals as set out in the national regulations must be adhered
to.
The date of manufacture is shown on the inside of the face seal in the chin area.
Cleaning/Disinfection
We recommend cleaning the mask after each use. Remove the filter; clean the
facepiece with warm water (max. 50°C). If necessary, use a neutral cleaning
agent and an alcohol-based disinfectant. To clean the valve membrane, remove
it from the holder. To dismantle the filter, refer to the instruction manual for gas
and particulate filters. Dry the mask thoroughly before storing it.
Storage
Keep the 7000 mask sealed in a dry, uncontaminated environment. Protect it
against sunlight and sources of heat. The name of the wearer and a record of the
filter changes can be noted on the packaging. The date of manufacture is en-
graved on the inside of the mask. Calendar clocks see page 41.
Exhalation Valve Spare Part No. 9973
Fold up the cover of the exhalation valve and check the exhalation valve and the
valve seat for contamination, deformation, fractures or cracks. If necessary,
replace the valve membrane, every 4 years at the latest.. Please note date of
replacement.
Inhalation Valve Spare Part No. 9973
Check the inhalation valve on the inside of the filter connection for contamination,
deformation, fractures or cracks. If necessary, replace the valve. When fitting the
valve, make sure that it fits completely beneath the three hooks on the mounting
and that it rests evenly on the valve seat.
Head Straps Spare Part No. 7972
To fit the new straps, fold up the cover of the exhalation valve.
All warranties are void if the product is not stored, used, maintained and
serviced according to the instructions provided here or if the product is
not used accordance with the relevant regulations.
Overview of the various types of masks/filters and their
application limits
Description/
Mask Type
Size Model
Facepiece size small S 7001
Facepiece size medium M 7002
Facepiece size large L 7003
Table 1
Half-mask Series 7000 with...
Protection factor/
Maximum Use Level
P1 R Particulate Filter 4 x WEL
P2 R Particulate Filter 10 x WEL
P3 R Particulate Filter 20 x WEL
Class 1 Gas Filter
10 x WEL or 1000 ppm
(whichever is lower)
Class 2 Gas Filter
10 x WEL or 5000 ppm
(whichever is lower)
WEL = Workplace Exposure Limit
Marked R: The filters are reusable.
Use of the filter is described in the instruction manual for gas and particulate