3.3 Electrical Specifications
3.3.1 Absolute Maximum Ratings
Absolute maximum ratings for supply voltage and voltages on digital and analogue pins of the
module are listed below; exceeding these values causes permanent damage.
3.3.2 Recommended Operating Parameters
When the VCC is 3.3V, the performance will be the best. The operating voltage range is 1.9V-3.6V.
3.4 RF Specifications
3.4.1 LoRa Frequency vs Tx Power
Test condition: VCC=3.3V, 25°C, SF10/BW125K
Frequency/MHz
Max Tx Power/dBm
Test Frequency/MHz
Frequency Offset/ppm
903.9
20.7
903.8992
-0.885053656
904.1
20.6
904.0991
-0.995465103
904.3
20.7
904.2991
-0.995244941
904.5
20.7
904.4992
-0.884466556
904.7
20.7
904.6992
-0.884271029
Parameter
Minimum
Maximum
Unit
Voltage at VCC
-0.3
+3.6
V
Storage temperature
-40
85
ºC
Parameter
Minimum
Type
Maximum
Unit
Voltage at VCC
3.27
3.3
3.33
V
Storage
temperature
-40
25
85
ºC