Specification V1.0

LW005-MP
15 www.mokosmart.com
Load state payload will be sent in Port 13.
Timestamp: Standard UTC time.
Time zone: It is a signed number, convert to decimal, then then divide by 2, and this is UTC
time zone;
Change of load state: 00 means load starts stop; 01 means load starts working
7.9 Countdown Payload
Countdown payload will be sent in Port 14.
Timestamp: Standard UTC time.
Time zone: It is a signed number, convert to decimal, then then divide by 2, and this is UTC
time zone;
ON/OFF state after countdown process ends: 00 means OFF; 01 means ON.
Time remaining of the countdown process: Convert to decimal, the unit is S(second).
Byte 0~3
Byte 4
Byte 5
Timestamp
Time zone
Change of load state
Byte 0~3
Byte 4
Byte 5
Byte 6-9
Timestamp
Time zone
ON/OFF state after countdown process ends
Time remaining of the
countdown process