APP Configuration Guide V1.0

LW005-MP
9 www.mokosmart.com
When the plug detects that the measured voltage/current/power exceeds the safe range for a
period of time, it will automatically turn off the switch.
The rated current and voltage of different plug types are not the same, so the power, voltage and
current threshold configurations are also different, please set the threshold value according to the
plug types.
Type
Parameter
Description
Over-load
protection
Power threshold
EU/FR plug: Default: 4416, range: 10-4416 (unit: W)
US plug: Default: 2160, range: 10-2160(unit: W)
UK plug: Default: 3588, range: 10-3588 (unit: W)
Time threshold
Default: 4, range: 1-30 (unit: second)
Over-voltage
protection
Voltage threshold
EU/FR plug: Default: 253, range: 231-264 (unit: V)
US plug: Default: 132, range: 121-138 (unit: V)
UK plug: Default: 253, range: 231-264 (unit: V)
Time threshold
Default: 4, range: 1-30 (unit: second)
Sag-voltage
protection
Voltage threshold
EU/FR plug: Default: 207, range: 196-229 (unit: V)
US plug: Default: 108, range: 102-119 (unit: V)
UK plug: Default: 207, range: 196-229 (unit: V)
Time threshold
Default: 4, range: 1-30 (unit: second)
Over-current
protection
Current threshold
EU/FR plug: Default: 19.2, range: 0.1-19.2 (unit: A)
US plug: Default: 18, range: 0.1-18 (unit: A)