2.3.2 General Settings
In this page, user can configure general parameters:
2.3.2.1 Switch Control
Time Sync Interval: It is used to sync the device time via MAC
command. The default is 1, means that the device's time will be
synchronized every 1 hour via LoRaWAN MAC commands.
The value ranges from 0 -255H. 0 means disable.
Network Check Interval: The device will periodically check the
LoRaWAN network status via MAC command. The default is 1,
means that the device will check the network status every 1 hour via
LoRaWAN MAC commands.
The value ranges from 0 -255H. 0 means disable.
ON/OFF: User can control the AC output of the LW005-MP.
Report Interval: The report interval of switch payloads.
The default is 30, the unit is s.
The value ranges from 10 -600s.