User Manual Part 4

Administration Tab
SpectraGuard® Enterprise User Guide
186
Note: When you import sensors from a list, you can delete these sensors only from the Devices screen.
Thresholds
Threshold settings determine the status of devices in terms of up-down association and connectivity. The Thresholds
screen enables you to set parameters for APs, clients, and sensors.
Device Thresholds
Device Threshold Parameters contains the following settings:
AP Timeout
Activity Timeout: If the system senses no activity of the AP for the period specified here, it
declares the AP inactive.
(Minimum: 60 seconds; Maximum: 600 seconds; Default: 300 seconds)
Client Timeouts
Activity Timeout: If the system senses no activity from a Client for the period specified here, it
declares the Client inactive.
(Minimum: 120 seconds; Maximum: 1200 seconds; Default: 600 seconds)
Association Timeout: If the system sees no communication between an associated AP and Client pair for
the period specified here, it declares the association as timed out.
(Minimum: 120 seconds; Maximum: 1200 seconds; Default: 600
Sensor Parameters
Maximum Number of Sensors Allowed: Maximum number of sensors allowed to connect to the
system at a given time.
(Maximum value is governed by the license applied and is a Read-Only field.)