User's Manual


SS300ATC60InstallationGuide
Figure 17. Edit Serial Port Settings for Sensor SS-300-AT-C-60
Edittheserialportsettingsasfollowsorclick<RestoreDefaults>toensurepropercommunicationbetweenthe
Sensorandyourcomputer.
Bitspersecond:115200
Databits:8
Parity:None
Stop
bits
:1
Flowcontrol:None
Click<OK>ontheCOMPropertiesdialog.
Press<Enter>or<Space>ontheHyperTerminalscreen.
5.2.2 LoginandChangetheDefaultPassword
LogintotheConfigShellusingtheusernameconfigandpasswordconfig.Changethedefaultpasswordusingthecommand
passwd
.YoucanchangetheSensorpasswordusingSensortemplates.Refertosection8.4.4:SensorConfigurationinthe
SpectraguardEnterpriseUserGuideformoredetails.
Recommended;AirTightrecommendsthat
youchangethedefaultpasswordforsecurityreasons,althoughitisnotmandatory.
5.2.3 SetServerDiscovery
ThenextstepistosettheServerDiscoveryinformation.TherearetwotypesofServerDiscovery.
ServerIPbaseddiscovery(preferred)
ServerIDbaseddiscovery(deprecated)
ServiceLocationProtocol(SLP)baseddiscovery(ifwifisecurityserverservicehasbeenconfigured)
Usethecommandsetserverdiscoverytopointthe
SensortothecorrectServer.
Figure 18. set server discovery command
Note:IfIP/Hostnamebaseddiscoveryisbeingusedandthereis morethanoneServeronthenetwork,thenyoumustentertheIPaddress
oftheappropriateServer .
5.2.4 SetSensorMode
ThenextstepistosetthemodeoftheSensor.Therearetwopossiblemodes: