Chapter5 ManuallyConfiguringthe SS‐300‐AT‐C‐60asSensor
Important:IftheinstallationinInstallingSS‐300‐AT‐C‐60wassuccessful,stop!Youdonotneedtoconfigurethedevicemanually.
5.1 Introduction
ManualconfigurationofSS‐300‐AT‐C‐60asaSensoristypicallyrequiredinthefollowingcases:
• DeviceneedstobeconfiguredinNDmode.
• SensorOnly(SO)devicescannotconnecttotheSpectraGuard®Enterpriseserverthroughzeroconfiguration.The
DNSentryfortheSpectraGuard®Enterpriseserverhasbeen
changedtoanentryotherthanʺwifi‐security‐serverʺor
thereisnoDNSServerpresentinthenetwork.Thisisapplicableformulti‐serverinstallations.
•
SensorisplacedonasubnetthatisnotDHCPenabled.
5.2 ConfiguringSensorthroughConfigShell
TousetheConfigShell,connectaSerial(RS‐232)cablebetweenyourcomputerandtheSensor.TheConfigShellsupportsa
pre‐definedsetofcommandsusedtoconfiguretheSensor.
Figure 13. Connecting SS-300-AT-C-60 to your computer using a Serial Cable
ThestepstoconfiguretheSensormanuallyareasfollows:
1. InvokeHyperTerminal(orminicom)
Loginandchangethedefaultpassw ord
SetServerDiscovery
SetSensorMode
SetNetworkSettingsforthatSensorMode
Theabovestepsareexplainedindetailbelow.
5.2.1 InvokeHyperTerminal (orminicom)
ToconfiguretheSensor,followthestepsdescribedbelowtoinvoketheConfigShell.
5.2.1. 1 LaunchingHyperTerminal
TostartHyperTerminal,clickStart
Programs
Accessories
Communications
HyperTerminalasshowninthefollowing
figure.