User's Manual
SS‐300‐AT‐C‐60InstallationGuide
Figure 4. Side Panel of SS-300-AT-C-60
Thesidepanelhasthefollowingports:
• Serialport:ConnectstheSS‐300‐AT‐C‐60devicetoserialterminalemulationprogramssuchasHyperTerminalfor
WindowsorminicomforLinux.
• USBport:ConnectstheSS‐300‐AT‐C‐60devicetoaUSBdevice.
• Resetswitch:Resets
theSS‐300‐AT‐C‐60devicetofactorydefaults.ToresettheSS‐300‐AT‐C‐60device,pressthe
Resetswitchandpowercycle(removethepowercableonceandconnectitbackagain)thedevice,untilallLEDs
blinkgreen.Pressing<Reset>whilethedeviceisrunning
willnothaveanyeffect.Thefollowingsettingsarereset:
ConfigShellPasswordisresettoconfig.
ServerDiscoveryvalueiserasedandchangedtothedefault,wifi‐security‐server.
AlltheVLANconfigurationsarelost.
DevicemodeischangedtoSensorOnly.
IfstaticIP
wasconfiguredonthedevice,theIPiseras edandDHCPmodeisset.
Afterreset,alltheLEDswillblinkonce,implyingthattheresetissuccessful.
Note:ForSS‐300‐AT‐C‐60,theuseris expectedtopressandholdtheresetswitchwhileapower‐cycle
for30seconds(actuallytakes26
secondsfortheresettocomplete).
Table 5. Side Panel Port Settings for SS-300-AT-C-60
Port Description Connector Type Speed/Protocol
Reset Allows resetting of
SpectraGuard Sensor™ to
factory settings.
Pin-hole
push-button
Hold down and power
cycle the Sensor to
reset
USB Connects the SS-300-AT-C-60
device to a USB device
Console Enables a serial connection to
establish terminal sessions.
Used for launching Config Shell
sessions.
RJ-45 RS 232 Serial
Bits per second:
115200
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None