User's Manual

ServerȱandȱSensorȱOverviewȱ
SpectraGuard
®
ȱEnterpriseȱInstallationȱGuideȱ
7ȱ
Solid
Orange
Solid
Green
Any Any The Sensor is unable to get Ethernet link.
Solid
Orange
Fast Blink Any Any
The Sensor did not receive a valid IP
address via the DHCP.
Solid
Orange
Slow Blink Any Any
The Sensor is unable to connect to the
Server.
Solid
Orange
Any
Solid
Green
Any
There is an error on 802.11a/b/g
interfaces.
Solid
Orange
Any Any
Solid
Green
The Sensor is experiencing a software
error.
Off Off Off Off
The Sensor is not powered on or it is in
the process of starting up.
ȱ
3.3.2 SensorȱSSȬ300ȬATȱ
TheȱfrontȱpanelȱofȱtheȱSensorȱhasȱLEDsȱthatȱindicateȱtheȱworkingȱofȱtheȱSensorȱ
ȱ
Figure 6. Front View of Sensor SS-300-AT
Table 5. LED Details for Sensor SS-300-AT
LED1 or
Power
LED2 or
LAN
LED3 or
802.11an
LED4 or
802.11
b/gn
Description
Solid
Green
Solid
Green
Solid
Green
Solid
Green
The Sensor is receiving power and is
working normally. The Sensor is
connected to the Server.
Solid
Green
Solid
Green
Solid
Green
Fast Blink
The Sensor is performing Troubleshooting
on 802.11b/g/n.
Solid
Green
Solid
Green
Solid
Green
Slow Blink
The Sensor is performing Intrusion
Prevention on 802.11b/g/n.
Solid
Green
Solid
Green
Fast Blink
Solid
Green
The Sensor is performing Troubleshooting
on 802.11a/n.
Solid
Green
Solid
Green
Fast Blink Fast Blink
The Sensor is performing Troubleshooting
on 802.11a/n and 802.11b/g/n.
Solid
Green
Solid
Green
Fast Blink Slow Blink
The Sensor is performing Troubleshooting
on 802.11a/n and Intrusion Prevention
on 802.11b/g/n.
Solid
Green
Solid
Green
Slow Blink
Solid
Green
The Sensor is performing Intrusion
Prevention on 802.11a/n.
Solid
Green
Solid
Green
Slow Blink Fast Blink
The Sensor is performing Intrusion
Prevention on 802.11a/n and
Troubleshooting on 802.11b/g/n.
Solid
Green
Solid
Green
Slow Blink Slow Blink
The Sensor is performing Intrusion
Prevention on 802.11a/n and
802.11b/g/n.