User's Manual

Manual Configuration of SpectraGuard Sensor
SpectraGuard Sensor Installation Guide
22
Note: If IP address assignment via DHCP fails, the default values assigned are as follows:
IP address = 192.168.3.58
Net Mask = 255.255.255.0
If DHCP fails, the Sensor software doesn't begin execution.
The following screen is an example from a live session.
Figure 18 Changing network settings using the setdhcpip command
setstaticip
This command allows you to assign a static IP address for the Sensor and prompts you for the
following inputs:
A valid IP addressóThe IP address should be compatible with the network segment on which
this SpectraGuard Sensor is to be connected.
The corresponding subnet maskóThis represents the mask of the network segment to which
the SpectraGuard Sensor will be connected.
$ setdhcpip
Stopping SpectraGuard Sensor...
Getting IP over dhcp...
Enter Route Settings or press Enter to skip settings routes
Route Settings:
Network ID:
Applying Changes...
Ethernet MAC Address = 00:11:74:20:10:C4
Boot IP Protocol = dhcp
IP=192.168.3.58 Mask=255.255.255.0 Gateway=