SP6647.qxd 7/5/06 8:23 AM Page 1 CAUTION: READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. SAVE THIS OWNER’S MANUAL FOR FUTURE REFERENCE. Model No. HD14070 ® MD TM MC HD14070 Evaporative Console Humidifier Owner’s Manual Part No.
SP6647.qxd 7/5/06 8:23 AM Page 2 Limited Warranty This product is warranted against defects in workmanship and materials for one year from the date of sale except for motors, which are warranted for two years.
SP6647.qxd 7/5/06 8:23 AM Page 3 Know Your Humidifier Fan Assembly Controls Bottles Filter Housing Filters: Replacement Filter HDC12 Pivoting Lid Humidistat (On Power Cord) Casters Pivoting Lid Removed For Clarity Description HD14070 * Output/24 hrs Capacity of Bottle * Sq. Ft.
SP6647.qxd 7/5/06 8:23 AM Page 4 How Your Humidifier Works Your new MoistAIR humidifier is designed to satisfy home humidity requirements through the principle of evaporation of water into the air. After water is added to the bottle, the filters begin to soak up the water and become totally saturated in approximately 30 minutes. Air is drawn in from the rear of the humidifier and through the filters by means of circulation fans.
SP6647.qxd 7/5/06 8:23 AM Page 5 Location Instructions next to an inside wall. Hot air registers and cold air from outside walls can affect the efficiencies of the controls. Unit should not be placed where warm air from a hot air register blows directly on unit. Moist air (humidity) produced will disperse into the whole house, but area closest to the unit will have the highest humidity. If the unit is positioned close to a window, condensation may form on the window pane.
SP6647.qxd 7/5/06 8:23 AM Page 6 Electrical Hook-Up If the plug does not fit fully in the outlet, reverse plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way. Locate nearest 120V A.C. wall socket in the location desired, preferably on inside wall. With the humidifier in the desired location, route the electrical cord safely so no one will trip or upset the humidifier. Plug in the electrical cord.
SP6647.qxd 7/5/06 8:23 AM Page 7 Water Fill (continued) Each water bottle is designed with a “Side-Fill Cap” that is easily removable. Remove the “Side-Fill Cap” on the side of the water bottle by twisting counterclockwise. Turn Counterclockwise to Remove Cap Place the opening of the water bottle under a water faucet (the bottle should fit under a four-inch clearance faucet). Fill with recommended mixture of cold water and Bacteriostat (if necessary) only. Solid debris could make the valve leak.
SP6647.qxd 7/5/06 8:23 AM Page 8 Operating the Controls Function Buttons Where you set your desired humidity levels depends on your personal comfort level, outside temperature and inside temperature. A starting set point of 30% 40% ROOM humidity is recommended but there may be conditions that require a different setting. IMPORTANT: Water damage may result if condensation starts to form on windows or walls. Humidity SET point should be lowered until condensation no longer forms.
SP6647.qxd 7/5/06 8:23 AM Page 9 Operating the Controls (continued) The SET readout has a range of 25% to 65% and is adjusted in increments of 5%. Initially depressing the humidity button will display the current humidity setting. Each additional press of the button increases the setting by 5%. A SET point of 65% operates the humidifier continuously regardless of the ROOM reading. The humidistat that senses the readings is located on the power cord. Insure that this humidistat is free from obstruction.
SP6647.qxd 7/5/06 8:23 AM Page 10 Using Your Humidifier (continued) Check Filter Indicator The ability of any humidifier to efficiently supply humidity output relies heavily on the condition of the filter. As the filter loads with impurities it gradually loses its wicking capability. When this happens, moisture output is reduced and the humidifier has to work longer to satisfy the selected setting. This humidifier has a check filter reminder timed to appear after 720 hours of motor operation.
SP6647.qxd 7/5/06 8:23 AM Page 11 Replacement and Care of Filters Pivoting Lid Fan Assembly WARNING: To reduce the risk of shock or injury from moving parts, always unplug humidifier before removing or replacing any parts. CAUTION: To help retard bacteria growth and keep maximum efficiency, the filter should be replaced at least once per season, or more often under hard water conditions. Use MoistAIR HDC12 recommended replacement filter.
SP6647.qxd 7/5/06 8:23 AM Page 12 Replacement and Care of Filters (cont’d.) e. Replace the filter housing in the cabinet. Top Cover NOTE: There is a front and back orientation. To position the filter housings correctly: • Be sure that the spring tabs of filter housings are towards front of cabinet. • Align the lower portion of the filter assembly over the six ribs located at the bottom rear of the humidifier cabinet. f. Position fan assembly onto the cabinet.
SP6647.qxd 7/5/06 8:23 AM Page 13 Cleaning and Maintenance (cont’d.) Refill humidifier bottles with fresh cool water and return them to the cabinet. Plug the unit into a 120 volt A.C. power outlet and set the controls per the “Operating Humidifier Controls” section (page 8) of this manual. WARNING: To reduce the risk of shock, always unplug humidifier before cleaning or servicing. If humidifier is not unplugged, fan could start after housing is removed.
SP6647.qxd 7/5/06 8:23 AM Page 14 Troubleshooting Probable Cause Remedy Digital display not illuminated. • No Power. • Power button has not been depressed. • Check 120 volt power source. • Press power button once to turn on. Fan not operating (digital display is illuminated). • ROOM humidity level is not 3% or • Raise SET humidity level if more below SET humidity level. desired. • Reservoir is empty. • Increase fan speed. • Fill humidifier with water.
SP6647.qxd 7/5/06 8:23 AM Page 15 Repair Parts Parts List for MoistAIR® Humidifier Model No.
SP6647.qxd 7/5/06 8:23 AM Page 16 Repair Parts Parts List for MoistAIR® Humidifier Model No. HD14070 MD Always order by part number - Not by key number Key No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 — Part No. Description 828741-2 Lid, Stationary 828855-2 Lid, Pivoting 831680-1 Control Assembly 824690 “Side-Fill Cap” 828192 Bottle, Left (Includes Key Nos. 4 & 7) 828726 Bottle, Right (Includes Key Nos.
SP6647.qxd 7/5/06 8:23 AM Page 18 FOR TECHNICAL HELP, CALL (800) 654-3545 FROM USA OR (888) 744-4687 FROM CANADA (Please have complete model number) ® MD TM MC Emerson Tool Company For more information about MoistAIR® humidifiers, visit our website at www.moistair.com MD c 2006 Emerson Part No. SP6647 Form No.