Installation Guide

MOHAWK TECHNICAL SERVICES – HARD SURFACE | MOHAWK_TECH@MOHAWKIND.COM | 888.387.9881 1687_2020 | ES | 10/2020 | 5 of 8
is lying at before trimming off the excess material. Apply caulk around the toilet, next to the bathtubs and showers to prevent moisture from getting
under the vinyl. NOTE: if there is a ceramic sanitary cove and no place to install trim mold, you can apply caulk around the walls.
Make sure furniture legs have large surface, non-staining plastic oor protectors or non-staining felt pads. The protectors should be at least one inch in
diameter and rest at on the oor. The heavier the item, the wider the oor protector should be. Replace small, narrow metal or dome-shaped glides
with smooth, at glides that are in at contact with the oor.
Never tape around the perimeter of the room.
Never apply Mohawk ooring to a wet adhesive (if adhesive is needed for certain areas of the Loose-Lay). This could cause permanent bond or wrinkling
and possibly void the warranty.
Permanent Full Spread Installation Method
Materials Required for Installation:
1/16” X 1/32” X 1/32” U notch trowel
Roberts 2310
Roberts 7500 Seam Sealant
Henry 366 Primer
Sharp Utility Knife
Straight edge
Plastic putty knife
2 clean cloths and appropriate cleaner
Acceptable Underlayment:
Wood underlayment
Wood underlayment panels require a double layer construction and must be underlayment grade as specied and warranted by the manufacturer.
Always fasten underlayment panels in accordance with the manufacturer’s recommendations. Any failure of the underlayment or Mohawk ooring as
a result of the underlayment is NOT the responsibility of Mohawk. Any porous wood underlayment must be primed.
Concrete – See Grade Levels below:
Grade Levels
Suspended: An acceptable suspended oor is a concrete or wood substrate with a minimum of 18” (460mm) of well-ventilated air space beneath it. Mohawk
recommends that a moisture vapor barrier be placed on the ground below the air space.
On-Grade: An acceptable on-grade oor is a concrete substrate in direct surface contact with the ground at the surrounding ground level. The concrete slab
should be protected from moisture penetration and incorporate a proven moisture vapor barrier.
Below-Grade: An acceptable below-grade oor is a concrete substrate partially or completely in contact with the ground below the average surrounding ground
level. The concrete slab should be protected from moisture penetration and incorporate a proven moisture vapor barrier.
VCT (well bonded, on and above grade)
Ceramic (well bonded)
Terrazzo (well bonded)
Self-leveling and patching compounds (latex fortied Portland cement based only)
Resilient oor (no more than 1 layers, well bonded, non-cushioned – residential applications only)
Radiant heat oors (not exceeding 85°F [29°C] and approved by the manufacturer for the use of their product with resilient vinyl ooring applications)
OSB (underlayment grade)
OSB underlayment panels must be underlayment grade as specied and warranted by the manufacturer. Underlayment panels and joints must be
fastened and reinforced according to manufacturer’s instructions. Completely sand the oor with a oor sander, so that the oor is smooth and at.
Note: The chips in OSB overlap. Without sanding properly, OSB has high and low spots throughout the oor that could telegraph through the vinyl.
Surface must be primed using Henry 366 Primer.