SDS

Date Printed: 11/17/2017 Product: M285-3003B
GHS SDS PRECAUTIONARY STATEMENTS
P240 Ground/bond container and receiving equipment.
P241 Use explosion-proof electrical/ventilating/lighting/ equipment.
P242 Use only non-sparking tools.
P243 Take precautionary measures against static discharge.
3. Composition/Information on ingredients
Chemical Name CAS-No. Wt. % GHS Symbols GHS Statements
ethanol
64-17-5
25-40 GHS02
H225
titanium dioxide
13463-67-7
10-25 No Information
No Information
butanol 71-36-3 10-25 GHS02-GHS05-
GHS07
H226-302-315-318-332-335-336
pm acetate
108-65-6
2.5-10 GHS02-GHS07
H226-332
isopropanol
67-63-0
1.0-2.5 GHS02-GHS07
H225-302-319-336
aliphatic petroleum distillates
64742-88-7
1.0-2.5 GHS06-GHS08
H304-331-372
aliphatic petroleum distillates
64742-47-8
1.0-2.5 GHS06-GHS08
H304-331
carbon black
1333-86-4
0.1-1.0 GHS02
H251
The exact percentage (concentration) of ingredients is being withheld as a trade secret.
The text for GHS Hazard Statements shown above (if any) is given in the "Other information" Section.
4. First-aid Measures
FIRST AID - EYE CONTACT: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and
easy to do. Continue rinsing.
FIRST AID - SKIN CONTACT: IF ON SKIN: Wash with plenty of soap and water.
FIRST AID - INGESTION: IF SWALLOWED: rinse mouth. Do NOT induce vomiting. IF exposed or if you feel unwell: Call a POISON
CENTER or doctor/physician.
FIRST AID - INHALATION: IF INHALED: If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable
for breathing. IF exposed or if you feel unwell: Call a POISON CENTER or doctor/physician.
5. Fire-fighting Measures
SPECIAL FIREFIGHTING PROCEDURES: Evacuate all persons from the fire area to a safe location. Move non-burning material, as
feasible, to a safe location as soon as possible. Fire fighters should be protected from potential explosion hazards while extinguishing
the fire. Wear self-contained breathing apparatus (SCBA) and full fire-fighting protective clothing. Thoroughly decontaminate all
protective equipment after use. Containers of this material may build up pressure if exposed to heat (fire). Use water spray to cool
fire-exposed containers. Use water spray to disperse vapors if a spill or leak has not ignited. DO NOT extinguish a fire resulting from
the flow of flammable liquid until the flow of the liquid is effectively shut off. This precaution will help prevent the accumulation of an
explosive vapor-air mixture after the initial fire is extinguished.
FIREFIGHTING EQUIPMENT: This is a NFPA/OSHA Class 1B or less flammable liquid. Follow NFPA30, Chapter 16 for fire
protection and fire suppression. Use a dry chemical, carbon dioxide, or similar ABC fire extinguisher for incipeint fires. Water may be
used to cool and prevent rupture of containers that are exposed to heat from fire.
6. Accidental Release Measures
ENVIRONMENTAL MEASURES: No Information
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED: Follow personal protective equipment recommendations
found in Section VIII. Personal protective equipment needs must be evaluated based on information provided on this sheet and the
special circumstances created by the spill including; the material spilled, the quantity of the spill, the area in which the spill occurred,
and the training and the expertise of employees in the area responding to the spill. Never exceed any occupational exposure limits.
US_GHS_SDS (English)
Page 2 / 7