Technical Specifications

GAITWOOD 2.0 MM/10 MIL- TECHNICAL DATA SHEET
PHYSICAL PROPERTIES (FLOATING MULTILAYER MODULAR FLOORING) 2.0MM GAUGE / 10MIL WEAR LAYER
Collection
Plank - Wide
Overall Gauge
2.0 mm (0.079”)
Wear Layer
10 mil (0.254mm)
Core
1.7mm (0.069”)
Core Density
1.08 grams / cm³
Pad
No attached pad
Use
Light Commercial & Residential
Profile
Flex LVT
Finish
Mechanically Embossed
Embossing(s)
Limited Warranty
Residential Limited 15 year/ Light Commercial Limited 6 year
Size
6.0”x 36” (203mm x 914.4mm)
Pieces/Carton
12 pcs
Coverage/Carton
18.00 Sq Ft (1.67 Sq M)
STANDARDS SAFETY & PERFORMANCE
Standard
Description
Requirements
Results
ASTM F970
Static Load
≤0.003” at 250 psi
Passes Requirements
ASTM F970
Static Load Limit
Test to Limit (±0.006”)
1100 psi
ASTM F2199
Dimensional Stability
≤0.25% / lineal ft.
Passes Requirements
ASTM F2421
Squareness
Max 0.010” (0.25mm)
Pass Requirements
ISO 4918
Castor Wheel Test
25,000 cycles
Passes Requirements
ASTM D4060
Abrasion Resistance
Not Applicable (No Official Requirements)
16,000 cycles
ASTM F925
Chemical Resistance
No more than “Slight Change”
Passes Requirements
ASTM F1514
Resistance to Heat
Average ΔΕ < 8.0
Passes Requirements
ASTM F1515
Resistance to Light
Average ΔΕ < 8.0
Passes Requirements
ASTM E648
Critical Radiant Flux (Radiant Panel)
Class I: ≥ 0.45 W/cm
1
Passes Requirements
1
ASTM E662
Smoke Density
≤ 450 Flaming & Non-Flaming
2
Passes Requirements
2
ASTM D2047
Coefficient of Friction (Slip Resistance)
Not Applicable (No Official Requirements)
0.6 (Dry, Wet)
AATCC 134
Electrostatic Propensity
Not Applicable (No Official Requirements)
≤ 2.0 kV Max Avg
ASTM F963
Heavy Metals
Refer to Standard
Passes Requirements
ASTM D7823
Phthalates
Refer to CPSIA
3
Passes Requirements
STANDARDS SOUND
Assembly
ASTM E90
ASTM E492
Results (Remarks)
6” Concrete Slab
STC 52
IIC 52
All tested assemblies pass IBC
4
requirements of
STC ≥ 50 and IIC ≥ 50 for multi-story dwellings
8” Concrete Slab
STC 62
IIC 72
6” Concrete Slab with Drop-Ceiling
STC 60
IIC 59
8” Concrete Slab with HPPC
5
STC 62
IIC 72
Notes
1) ASTM E648 - Critical Radiant Flux (Radiant Panel): Passes Requirements for Class I per International Building Code (IBC) 2018 & NFPA 101 Life Safety Code
2) ASTM E662 - Smoke Density: 450 is the limit established by many state, county, and/or local building and/or fire codes, but is not set as a limit for (resilient) flooring products
nationwide. Thus, Smoke Density requirements for flooring products may vary from jurisdiction to jurisdiction.
3) CPSIA = Consumer Product Safety Improvement Act
4) IBC = International Building Code
5) HPPC = High performance partition construction
Effective: April 6, 2020 Page 1 of 1