Specifications Part 2

Page 2 of 5 6065-M (2016_7_6)
M. ASTM F137: Standard Test Method for Flexibility of Resilient Flooring Materials with Cylindrical Mandrel
Apparatus
N. ASTM F1515: Standard Test Method for Measuring Light Stability of Resilient Flooring by Color Change
O. ASTM F1514: Standard Test Method for Measuring Heat Stability of Resilient Flooring by Color Change
1.4 SUBMITTALS
A. Provide the product’s Technical Specifications data sheet as well as all Installation and Maintenance
Instructions.
B. When required, supply floor drawings and installation plans.
C. Supply a set of samples measuring at least 3” (7.5 cm) by 6” (15 cm) of the complete range of colors and
finishes chosen for the project.
D. When required, provide Mohawk Group’s attestation, certified by an independent laboratory, confirming that
the flooring complies with the fire standards of the following tests:
1. ASTM E 648; Critical Radiant Flux: 0.45 watts/cm
2
or more
2. ASTM E 662; Smoke Density: 450 or less
E. Provide Mohawk Group’s Warranty Certificate.
1.5 QUALITY ASSURANCE
A. Installer Qualifications: Installer experienced in installation or application of systems similar in complexity to
those required for this project, including specific requirements indicated.
B. In accordance with the technical instructions in the Installation Instructions, use all the accessories
recommended by Mohawk Group when installing its flooring.
NOTE TO SPECIFIER: Include a mock-up if the project size and/or quality warrant taking such a precaution. The
following is one example of how you might specify a mock-up on a large project.
C. Mock-up: Provide a mock-up for evaluation of surface preparation technique, application workmanship and
requirements for expansion control. Do not proceed with remaining work until workmanship, color, sheen
and finished appearance are approved by architect.
D. Follow the instructions specified in the most recent version of Mohawk Group’s Installation Instructions.
1.6 DELIVERY, HANDLING, STORAGE
A. Deliver the flooring to the installation site in Mohawk Group’s original packaging. Indicate the project name
and handling instructions on the outside of the boxes.
B. Advise the carrier of any damaged material and indicate it on the packing slip.
C. Store materials in a flat in a dry, warm, ventilated and weather tight location. Protect flooring products from
damage.
D. Install the flooring after all other finishing work, including painting, have been completed.
1.7 PROJECT CONDITIONS
A. Store the flooring inside, sheltered from extreme hot or cold temperatures. Place the material on a smooth
level floor or where there is uniform solid support in a clean, dry well-ventilated area. Unstack the pallets. The
long-term storage temperature must be maintained between 65°F (18°C) and 85°F (29°C). Protect adhesive
and flooring material from freezing, extreme heat and direct sun exposure.
B. Acclimatize the subfloor, all flooring material and adhesive for 48 hours before, during and after the
installation by maintaining the room temperature between 65°F (18°C) and 85°F (29°C). The pallets should be
unstacked 24 hours prior to use.
C. Afterwards, maintain the room temperature between 55°F (13°C) and 90°F (32°C). Protect the material from
direct sources of heat such as air vents and other types of heaters.