Specifications Part 2
Page 1 of 5 6065-M (2016_7_6)
160 South Industrial Blvd.
Calhoun, GA 30701
Section 096519
RESILIENT FLOORING: Petrology
This document is intended as a suggested guide for editing your architectural guide specification.
Mohawk Group will not be held liable for damages arising out of the use of any information or specifications found in this document. Make sure you
have the latest publication for this specification.
Product selection and accuracy of all project specifications are the specifier’s or designer’s responsibility.
PART 1 – GENERAL INFORMATION
1.1 SECTION INCLUDES
A. This section deals with resilient flooring found in the drawings and schedules of the contract that meet the
requirements of this section.
B. Related Documents: Drawings and general provisions of the contract apply to the work of this section.
1.2 RELATED SECTIONS
Note to Specifier: Delete any sections below not relevant to this project and add others as required.
A. Division 3 – Concrete: not covered in this section.
B. Division 6 – Wood and plastic: not covered in this section.
C. Division 7 – Thermal and humidity protection: not covered in this section.
D. Division 9 – Other sections containing information related to floor finishes: not covered in this section.
1.3 REFERENCES (INDUSTRY STANDARDS)
A. ASTM F 710: Practice for Preparing Concrete Floors to Receive Resilient Flooring.
B. ASTM E 648: Test Method for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy
C. ASTM E 662: Test Method for Specific Optical Density of Smoke Generated by Solid Materials.
D. ASTM F 1869: Standard Test Method for Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using
Anhydrous Calcium Chloride.
E. ASTMF 1700: Standard Specification for Solid Vinyl Tile. Class III, Type B Embossed
F. ASTM 2055: Standard Test Method for Determining Size and Squareness of Resilient Floor Tile by Dial Gauge
Method
G. ASTM F386: Standard Test Method for Thickness of Resilient Flooring Materials Having Flat Surfaces
H. ASTM 2199: Standard Test Method for Determining Dimensional Stability of Resilient Floor Tile after Exposure
to Heat
I. ASTM 970: Standard Test for Static Load Limit
J. ASTM 1914: Standard Test Method for Short-Term Indentation and Residual Indentation of Resilient Floor
Covering
K. ASTM D2047: Standard Test Method for Static Coefficient of Friction of Polish-Coated Floor Surfaces as
Measured by the James Machine
L. ASTM F925: Standard Test Method for Resistance to Chemicals of Resilient Flooring