Specifications
3
Specifications
Model Numbers Covered in this Specification
G592-B Gas Chargrill, 300mm wide - Bench Model.
G594-[2] Gas Chargrill, 600mm wide.
G596-[2] Gas Chargrill, 900mm wide.
G598-[2] Gas Chargrill, 1200mm wide.
NOTE: [2]: LS - On Leg Stand.
B - Bench Models.
General
A commercial heavy duty, fully modular, gas fired chargrill created for modular kitchens and can be
supplied in 4 different sizes with branding grates or optional griddle plates. Fitted with 300mm section
stainless steel burners. Individual ‘Hi'-'Lo' gas control to each burner and is fitted with piezo ignited
permanent pilot and flame failure protection for each burner.
Gas Supply Requirements
- Non CE Only:
- CE Only:
Appliance Classification
Category: II
2H3P
(20, 30 / 37).
Flue Type: A
1.
* - The burner operating pressure is to be measured at the manifold test point with one
burner
for G592 Model or two burners for other models operating at full setting. The
operating pressure is ex-factory set and not to be adjusted, apart from when converting
between gases, if required. (Refer to the ‘Gas Conversion’ section for details).
Natural Gas LP Gas (Propane)
G592 G594 G596 G598 G592 G594 G596 G598
Input Rating
(N.H.G.C.)
33.0 MJ/hr 66.0 MJ/hr 100.0 MJ/hr 133 MJ/hr 33.0 MJ/hr 66.0 MJ/hr 100.0 MJ/hr 133 MJ/hr
31,270 Btu/hr 62,500 Btu/hr 94,700 Btu/hr 126,000 Btu/hr 31,270 Btu/hr 62,500 Btu/hr 94,700 Btu/hr 126,000 Btu/hr
Supply Pressure
1.13 - 3.40 kPa
(4.5” - 13.5” w.c.)
2.75 - 4.50 kPa
(11” - 18.0” w.c.)
Burner Operating
Pressure
1.0 kPa 0.95 kPa (*) 2.5 kPa 2.6 kPa (*)
(4” w.g.) (3.8” w.g.) (9.8” w.g.)
Gas Connection
1
/
2
” BSP Male
3
/
4
” BSP Male
1
/
2
” BSP Male
3
/
4
” BSP Male
(10” w.g.)
Natural Gas (G20) Propane (G31)
G592 G594 G596 G598 G592 G594 G596 G598
Heat Input
(nett)
Nominal
8.8 kW 18.0 kW 27.0 kW 36.0 kW 8.8 kW 18.0 kW 27.0 kW 36.0 kW
Reduced
3.5 kW 6.0 kW 9.0 kW 18.0 kW 3.7 kW 6.4 kW 9.6 kW 12.8 kW
Gas Rate
(nett)
Nominal
0.93 m
3
/hr 1.90 m
3
/hr 2.86 m
3
/hr 3.81 m
3
/hr 0.68 kg/hr 1.40 kg/hr 2.10 kg/hr 2.80 kg/hr
Reduced
0.37 m
3
/hr 0.63 m
3
/hr 0.95 m
3
/hr 1.27 m
3
/hr 0.29 kg/hr 0.50 kg/hr 0.75 kg/hr 0.99 kg/hr
Supply Pressure 20 mbar 30 / 37 mbar
Burner Operating
Pressure
10.6 mbar 10 mbar (*) 25 mbar
Gas Connection
1
/
2
” BSP Male ¾” BSP Male
1
/
2
” BSP Male
3
/
4
” BSP Male
26 mbar (*)