Installation and Operation Manual Gas Target Top Range Electric Ovens RN8110GE RN8110GEC RNL8110GE RNL8110GEC Date Purchased Serial Number Dealer Service Provider 232456-10
MANUFACTURED BY Moffat Limited Christchurch New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat Pty Limited E.Mail: Main Office: Service: Spares: Customer Service: vsales@moffat.com.au (tel): +61 (03) 9518 3888 (fax): +61 (03 9518 3833 (tel): 1800 622 216 (tel): 1800 337 963 (tel): 1800 335 315 (fax): 1800 350 281 CANADA Serve Canada Web: E.Mail: Sales: Service: www.servecanada.com info@servecanada.com (tel): 800 551 8795 (Toll Free) (tel): 800 263 1455 (Toll Free) NEW ZEALAND Moffat Limited Web: E.
Contents Waldorf Gas Target Top Range Electric Oven RN(L)8110GE Gas Target Top Range Electric Static Oven. RN(L)8110GEC Gas Target Top Range Electric Convection Oven. Introduction .............................................................................................. 2 Specification ..............................................................................................
Introduction We are confident that you will be delighted with your WALDORF Gas Target Top Range Electric Ovens and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new Waldorf appliance, there are two important things you can do. Firstly: Please read the instruction book carefully and follow directions given. The time taken will be well spent.
Specifications Model Numbers Covered in this Specification RN[1]8110GE Gas Target Top Range Electric Static Oven - 900mm. RN[1]8110GEC Gas Target Top Range Electric Convection Oven - 900mm. NOTE: [1]: - Back Options; L - Standard Models. - Low Back Models. General A commercial heavy duty, gas fired Target Top having a high output, two stage double-ring cast iron burner offering accurate temperature control and infinitely variable heat with heat radiating out from centre of Target Top.
Specifications Electrical Supply Requirements 1-Phase Connection 1P+N+E, 230-240V MODEL 3-Phase Connection 3P+N+E, 400-415V RN8110GE 6.5 kW, 26.6 Amps @ 235 V 6.5 kW L1 - 8.2 Amps L2 - 9.2 Amps L3 - 9.2 Amps RN8110GEC 6.8 kW, 27.9 Amps @ 235 V 6.8 kW L1 - 9.5 Amps L2 - 9.2 Amps L3 - 9.2 Amps Electrical Connection Electrical supply connection point is located at rear of appliance, approximately 80mm from right hand side, 466mm from rear and 150mm from floor.
Dimensions Dimensions RN(L)8110GE / GEC 5
Installation Installation Requirements NOTE: It is most important that this appliance is installed correctly and that operation is correct before use. Installation shall comply with local gas, electrical and health and safety requirements. This appliance shall be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of health harmful substances in the room, the appliance is installed in.
Installation Clearances NOTE: Only non-combustible materials can be used in close proximity to this appliance. Combustible Surface Non Combustible Surface Left / Right hand side 50mm 0mm Rear 50mm 0mm * Side clearances can be 50mm when adjacent surface is at least 100mm below cooking surface. Assembly This model is delivered completely assembled. Ensure legs are securely attached.
Installation Gas Connection NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY AN AUTHORISED PERSON. 1. It is essential that gas supply is correct for appliance to be installed and that adequate supply pressure and volume are available. The following checks should be made before installation:a. Gas Type the appliance has been supplied for is shown on coloured stickers located above gas connection and on rating plate. Check that this is correct for gas supply the appliance is being installed for.
Installation Manifold Test Point NOTE: Measure burner operating pressure at manifold test point with target top burner (Inner and outer ring) operating at full setting. 7. 8. 9. Turn ‘Off’ mains gas supply and bleed gas out of appliance gas lines. Turn ‘On’ gas supply and appliance. Verify operating pressure remains correct. Fig 3 Electrical Connection Warning THIS APPLIANCE MUST BE EARTHED. IF SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY A SUITABLY QUALIFIED PERSON IN ORDER TO AVOID A HAZARD.
Installation NOTE: This appliance must be earthed. Fixed wiring installations must incorporate an all-pole disconnection switch. 9. 10. 11. Correctly locate appliance into its final operating position and using a spirit level, adjust legs so that appliance is level and at correct height. Connect power supply to appliance. Check electrical supply is within input rating specification, refer to 'Specifications' section). Commissioning 1. Before leaving the new installation; a.
Operation Operation Guide Caution This appliance is for professional use and is only to be used by qualified persons. Only authorised service persons are to carry out installation, servicing or gas conversion operations. Components having adjustments protected (e.g. paint sealed) manufacturer should not be adjusted by the user / operator. 1. 2. by the Waldorf appliances have been designed to provide simplicity of operation and 100% safety protection.
Operation Lighting Pilot Burner (Target Top) 1. Remove centre casting with casting removal tool. 2. Depress control knob and rotate anti-clockwise to ‘PILOT’ position. 3. With control knob depressed, manually light pilot burner located in front of main burner. 4. Hold in control knob for approximately 10 to 15 seconds, then release. 5. Pilot burner should remain alight. If not repeat Items 2 to 4 above until pilot burner lights. Lighting Main Burner (Target Top) 1.
Operation Oven ! IMPORTANT DO NOT USE aluminium foil or trays directly on cast iron sole plate(s). NEVER block or cover openings on each side of sole plate(s). The oven is fitted with top and bottom elements. The thermostat maintains overall oven temperature. Top element is further controlled by oven top heat control. Convection Ovens (RN8110GEC) are fitted with a circulation fan.
Cleaning and Maintenance General Caution Always turn ‘Off’ electrical and gas supply before cleaning. This appliance is not water proof. Do not use water jet spray to clean interior or exterior of appliance. Clean Target Top / Range regularly. A clean appliance looks better, will last longer and will perform better. Carbonised grease on cooking surfaces will hinder transfer of heat from cooking surface to food. This will result in loss of cooking efficiency.
Cleaning and Maintenance Target Top a. This should be kept clean of any build up of spillage’s of food. Provided the cast iron work surface is regularly used it will maintain itself in good condition with no special cleaning requirements required. b. Clean any food residue and spillage from channels around centre casting and main plates before use. c. DO NOT use water on castings while they are still hot as cracking may occur.
Fault Finding This section provides an easy reference guide to the more common problems that may occur during operation of your appliance. The fault finding guide in this section is intended to help you correct, or at least accurately diagnose problems with your equipment. Although this section covers the most common problems reported, you may encounter a problem not covered in this section.
Wiring Schematic RN(L)8110GE 17
Wiring Schematic RN(L)8110GEC 18
Wiring Schematic Wiring Layout for Static Oven Wiring Layout for Convection Oven 19
Gas Conversion and Specifications Conversion Procedure Caution Ensure Appliance is isolated from gas and electrical supplies before commencing servicing. NOTE: These conversions should only be carried out by qualified persons. All connections must be checked for leaks before re-commissioning appliance. Adjustment of components that have adjustments / settings sealed (e.g.
Gas Conversion and Specifications NOTE: Ensure pilot burner and thermocouple are correctly located and pilot burner aligns with main burner ignition port. (Refer to figure opposite for correct fitting and alignment dimensions). Pilot Burner Thermocouple Main Burner Ignition Port 2± 2.0 18± 2.0 Re-connect gas supply tube to pilot burner. Refit RH main fire brick. Refit 2 front fire bricks. Refit 2 half plate castings - ensure they are correctly interlocked. Refit centre casting.
Gas Conversion and Specifications Gas Type Identification Label On completion of the gas conversion, replace gas type identification label, located:- At the rear of the unit, above the gas connection. - Beside the Rating Plate. Commissioning Before leaving the converted installation; 1. Check all gas connections for leakages using soapy water or other gas detecting equipment. Warning DO NOT USE A NAKED FLAME 2. TO CHECK FOR GAS LEAKAGES.
Replacement Parts List Replacement Parts List IMPORTANT: Only genuine authorized replacement parts should be used for servicing and repair of this appliance. Instructions supplied with parts should be followed when replacing components. For further information and servicing instructions, contact your nearest authorized service branch (contact details are as shown on reverse of front cover of this manual). When ordering replacement parts, please quote part number and description as listed below.
Replacement Parts List General 227012 227013 014997 227892 227893 227896 228571 227963 227962 227850 229674 Centre Casting. Half Plate Casting. Casting Removal Tool. Side Rack LH. Side Rack RH. Oven Rack. Index Mark Moulding. Neon Orange. Neon Green. Leg (150 mm) Adjustable. Rear Roller Assy. Accessories 228800 Ranges 900 mm Plinth Kit. Gas Regulator Gas Type Gas Regulators Part No. Description Nat. Gas LPG Butane 228531 ¾” BSP F/F Convertible. Town Gas 230185 ¾” BSP F/F Adjustable.