FAULTFINDING
HELPFULHINTS
ShouldtheInverterappeartobemalfunctioningwesuggestthe
followingtoeliminateanyexternalproblems:
1. TurntheInverter“OFF”viatheCircuitBreakerswitchonthefrontpanel.
2. DisconnectallACwiringfromtheInverter.
3. DisconnectDCBatteryleadsfromBattery.Cleanallterminalsby
removingallgrease/corrosiononbothDCleadsandBattery
terminals.
4. EnsureyouhavesufficientBatterycapacityatthenominalvoltage
(specifiedonthecompliancelabelofyourInverter).
Pleasenote:Useminimum100AHBatteryorthesizeof
asubstantialCarBattery.
5. MakeconnectiondirectlytoBatteryterminalsandensureall
connectionsaretight.
7. EnsureBatteryvoltageiswithinthecorrectlimitsasoutlinedinthe
section ofthismanual.Ifyoudonot havea
DCvoltmeterormultimetercheckthefrontpanelforOvervoltsand
Undervolts EDs.
8. TurntheInverterONviatheCircuitBreakerswitchonthefrontpanel.
ObservethelightsonthefrontleftofyourInverter.Referto
forexplanationofIndicatorlights.
9. PluginvariousappliancesandmonitortheInvertersoperation.
* RememberthattheInverterautomaticallystartswhenaloadis
applied.
* Makesureleadsandterminalsarenotcorrodedorfaultyinanyway.
* MakesuretheInvertergoesintoSTANDBYwithnoloadswitchedon.
* MakesuretheCircuitBreakerisresetproperly.IfunsureswitchOFFand
ONagain.
6. RemoveotherwiringfrombatterytoensurethattheInverteristheONLY
deviceconnectedtobatterybank
sections
* Inextremeweatheritissuggestedtoshutdownandunplugtheunit.
INVERTERSPECIFICATIONS
INVERTER
OPERATION
L
DIPSWITCHSETTINGS
Dipswitchsettingsapplytoallmodelsfrom1000W-1800Winclusive.
InordertoaccesstheseoptionsyouhavetoopentheInverter.Before
alteringthesettingsswitchtheInverterOFF,adjustthesettingandswitchthe
InverterbackONagain.Werecommendtheseadjustmentsbecarriedoutby
qualifiedpersonneloryoursysteminstaller.
IfyouneedtooperateAmericanorJapaneseequipmentthisoptionwill
allowyourInvertertooperateat60Hz.
ThisfeatureisdesignedtorestarttheInverterandmaintainpowerintheevent
ofanexternalfault.ShouldtheInvertershutdownduetoundervoltage,over
temperatureoranyfaultconditionitwillattempttoresetevery8minutesuntil
thefaultconditionclearsandnormaloperationresumes.
ForoverloadshutdowntheInverterwillonlyattempt5restarts.IftheInverter
cannotresumenormaloperationwithin5restarts,itwillremainOFFuntilreset
manually.Thispreventscontinuousre-applicationofpowertofaulty
appliancesorwiring.
ForundervoltageshutdowntheInverterwillrestartwhenthebatteryvoltage
reachesthereconnectvalueasshowninthetablebelow.
SW5OFF&SW6OFF=(factorysetting)
SW1 Hz 50/60Hz
SW4 AR AutomaticReset
SW5&SW6 UV UnderVoltageSettings
Setting 12VValue 24VValue 48VValue
SW3 SP Special
SW5 SW6 DisconnectReconnect DisconnectReconnect DisconnectReconnect
ON ON 10.0 12.0 20.0 24.0 40.0 48.0
OFF OFF 10.5 12.5 21.0 25.0 42.0 50.0
ON OFF 11.0 13.0 22.026.0 44.0 52.0
OFF ON 11.5 13.5 23.027.0 46.0 54.0
ON=50Hz(factorysetting) OFF=60Hz
OFF=Disabled ON=Enabled (factorysetting)
SW2&
5