MANUAL and WARRANTY REGISTRATION CARD LS SERIES A NEW WORLD ® 500W to 1800W WALL MOUNT Please Affix Stamp Here technical@latronics.com.au email: technical@latronics.com email: LATRONICS P.O. BOX 73 MOFFAT BEACH QLD 4551 AUSTRALIA POWER www.latronics.com web: web: www.latronics.com.au 6988 5491 6988 7 5491 Ph Ph 61 7 Latronics P.O.
It is important to us at Latronics, that our clients enjoy the maximum benefits from our Inverters, in a safe and productive environment. We strongly advise that you read through the next few pages of this manual, which explains all the modes of operation and relevant safety precautions for your new Power Inverter. If your Inverter requires service or repair please complete the warranty repair form on page 19-20.
TABLE OF CONTENTS Please provide full description of fault ................................................................................................. PAGE INSTALLATION 2 BATTERIES 4 DIP SWITCH SETTINGS 5 AUTOMATIC TRANSFER SWITCH 7 ................................................................................................. INVERTER OPERATION 10 .................................................................................................
INSTALLATION • Ensure the Inverter has not been damaged in transit. • The Inverter must not be installed outside • The unit must be placed in a well-ventilated and protected area, not exposed to the open environment, and free from contaminates (i.e. exhaust gases, sea air, battery gases, dust). • A space of 10cm is needed on each side of the Inverter for adequate transfer of internal heat. • The Inverter can be mounted horizontally on a table or floor.
INVERTER MODEL LS-512 LS-648 LS-1012 LS-1224 LS-1248 LS-1512 LS-1824 LS-624 12V 24V 24V 48V 48V 12V 12V Nominal DC Voltage 24V 500W 1200W 600W 1200W 600W 1500W 1000W Continuous Power 1800W 550W 1600W 750W 1600W 750W 1600W 1150W 1/2 Hour Rating 2200W 1500W 3600W 2000W 3600W 2000W 4500W 3000W Surge Rating (5 Secs) 5400W 10.5-17V 21-34V 42-68V 10.5-17V 21-34V 42-68V 10.5-17V 21-34V Input Voltage Range 27mA 28mA 22mA 22mA 19mA 42mA 37mA Standby Current 30mA 0.42A 0.25A 0.31A 0.15A 0.15A 0.67A 0.
BATTERIES WARRANTY TERMS AND CONDITIONS FOR AUSTRALIA BATTERY SIZING It is important to match your Battery size according to the power rating of the Inverter. To ensure peak performance, it is important to choose the right Battery for your Inverter. The Battery size required will depend on the load and intended running time. Use this formula as a general guide: Recommended Battery Size = Inverter rating in watts ÷ input voltage × 10 e.g.
FAULT FINDING Should the Inverter appear to be malfunctioning we suggest the following to eliminate any external problems: 1. Turn the Inverter “OFF” via the Circuit Breaker switch on the front panel. 2. Disconnect all AC wiring from the Inverter. 3. Disconnect DC Battery leads from Battery. Clean all terminals by removing all grease/corrosion on both DC leads and Battery terminals. 4.
DECLARATION OF CONFORMITY DIP SWITCH LOCATION Manufacturer: Latronic Sunpower Pty Ltd 105 Grigor St West Moffat Beach Industrial Park Caloundra Queensland 4551 Australia MAIN PCB Declare that the LS series of inverters conform to the requirements of following standards 1 2 3 4 5 6 OFF DIP Switch located on Main PCB EN61000-6-1 EN61000-6-3 EN55014 AS1044 EN60335-1 AS3100 And therefore conform to the regulations of the EC directives Directive 2004/108/CE (EMC directive), Directive 2006/95/CE (low Voltage
RADIO FREQUENCY INTERFERENCE Radio Frequency Interference (RFI) is a phenomenon that exists in modern society and is a problem in many areas of electronics. For Inverter users, RFI normally presents itself in the form of static and/or interference when listening to an AM radio and in unusual cases may interfere with TV reception.
SAFETY Inverter Isolation and Safety Notes: ...................................................... ...................................................... ...................................................... ...................................................... ...................................................... ...................................................... ...................................................... ...................................................... ..........................
High efficiency even @ low levels Efficiency INVERTER EFFICIENCY & OUTPUT WAVEFORM 400 300 AC Voltage 200 100 0 -100 -200 -300 Notes: ...................................................... ...................................................... ...................................................... ...................................................... ...................................................... ...................................................... ...................................
INVERTER OPERATION When the Inverter is switched on all 3 LEDs light up for 1 second while the microprocessor performs a start up and system check procedure. Over temp./Over load (Red LED) If the internal temperature exceeds safe operating limits of the components for more than five seconds, the Inverter will shut down in Over temp with this LED on continuously. Allow 5 minutes for the Inverter to cool and reset the unit.