STONE INSTALLATION INSTRUCTIONS
INS
TA
LLING FINISHING TOU
CHES
HEARTHSTONE INSTALLATION INSTRUCTIONS
Note: Hearthstones are not recommended or warranted for exterior use or as a surface
area subject to foot traffic. Consult Surface Preparation Table 1 (page 2) for
requirements prior to installing hearthstones.
Place Mortar
Place mortar " deep in 3" wide strips 1" apart on prepared surface (Fig. 7).
Install Hearthstones
Place the first hearthstone onto the mortar bed and level (Fig. 8). Place adjacent
hearthstones, aligning and leveling with the first piece. If joints need additional
mortar, fill joints using a grout bag. Tool and finish joints following previous
instructions under Grouting & Finishing Joints (page 7). Ensure hearthstones are set
in a complete bed of mortar.
Note: Modulo Stone manufactured stone veneer and hearth products are made from
non-combustible materials. Mortar joints must not exceed " in width and the mortar
must be even with the top of the hearth surface.
RAISED HEARTH
Do not cantilever or extend Hearthstones more than 1" beyond direct support. When grouting the extended portion of
a cantilevered hearthstone, bring the grout to the front edge. Push a long galvanized nail horizontally into the grout to
add support, then cover the nail with mortar.
SEALING FIREPLACES / HEARTHS
If desired, sealing the Modulo Stone facing or hearth of a fireplace installation will assist in the removal of smoke and
soot stains should they occur.
WATERTABLE / SILL INSTALLATIONS
Watertables/sills provide a transition piece between a stone wainscot and other exterior finishes and for water runoff. They
can also be used as a windowsill. Install using galvanized metal support brackets (Simpson Strong Tie A-21 or other
galvanized right angle bracket with holding capacity minimum 5 lbs/LF) fastened with galvanized nails or screws penetrating
studs 1" at a minimum of 16" on center. Two brackets per sill is preferred if blocking is present. Use construction adhesive to
bond stone at bracket locations. Caulk and flash as required at watertable/ sill locations using an approved corrosion-
resistive flashing that extends to the surface of exterior wall finish and is installed to prevent water from re-entering the
exterior wall envelope.
Windowsill Cross Section Wainscot Cross Section
FIG. 7
PLACE MORTAR FOR
HEARTHSTONE INSTALLATION
FIG. 8
PLACE HEARTHSTONE
Caulk/Flashing
as Required*
Galvanized Wood
Screw
Watertable/Sill Stone
Construction
Adhesive (Bracket
Locations Only)
Galvanized Metal
Brack et, Holding
Capacity 5 lbs/LF
Mortar Se tting Bed
Lath
Modulo Stone
Product
Water-Resistive
Barrier
Lath
Interior Finish per
Schedule
2 × 4 Stud Wall
(Insulated)
Sheathing
Water-Resistive
Barrier
Exterior Finish per
Schedule
Flashing /Caulk
as Required*
Watertable/Sill Stone
Galvanized Metal
Bracket, Holding
Capacity 5 lbs/LF
Mortar Se tting Bed
Modulo Stone
Product
Construction
Adhesive (Bracket
Locations Only)
Galvanized Wood
Screw