V500S01 Brochure
1-150.14
23
PERFORMANCE DATA
Motor Data, Step-Down Transformer Accessory Data
➀
➁  
➂ 
➃ ➃, require that a 
➄➄
be used with a shipped loose accessory transformer. See Table 23.2 for Transformer Sizes.
Table 23.1 - Motor Data ➀ ➁
Figure 23.1  
Field Installed Transformer Accessory
Table 23.2 - Step-Down Transformer Accessory Selection
    208V/60Hz/1  230/460V/  575V/60Hz/
    or 3 phase   60Hz/3 phase  3 phase
  Model Number  kVA  kVA  kVA
  HSB/HC 18-63    0.25  0.25 
  HSB/HC 86-121    0.50  0.50 
  HSB/HC 165-193  1.00  0.75  0.75 
  HSB/HC 258-340    1.00  1.00 
  V/VN 42-59  0.50  0.25  0.25 
  V/VN 78-139    0.50  0.50 
  V/VN 161-212  1.00  0.75  0.75 
  V/VN 247-333    1.00 1.00 
  PT/PTN 279-333 1.00  1.00  1.00
  kVA Size  Ship Wt. (Lb.)
  0.25  7
  0.50  13
  0.75  15
  1.00  19
0.50
1.00
0.50
1.00
      Amp Draw by Motor Type, Voltage and Power Code
      115/60/1  208/60/1  230/60/1  208/60/3  230/460/3  575/60/3  115/60/1 230/460/60/3
  Model Number  Motor HP ➂ 01 N/A 02 04  05 10 06 09
  HSB/HC 18    ➃ 0.44  ➃  ➃  ➃ 4.3  -
  HSB/HC 24, 33    ➃ 1.0  ➃  ➃  ➃ 4.3  -
  HSB/HC 47, 63    ➃ 1.0  ➃ ➄  ➃ 4.3  -
  HSB/HC 86, 108    ➃ 1.0  ➃ ➄  ➃ 4.3  -
  HSB/HC 121    ➃  1.5 1.9 ➄ ➄  ➃  
  HSB/HC 165, 193    ➃  2.5 1.9 ➄ ➄  ➃  
  HSB/HC 258-340    ➃  3.5 2.6 ➄ ➄  ➃  
  V/VN 42, 59    ➃  0.6 1.9 ➄ ➄  ➃ 4.0  -
  V/VN 78, 95    ➃  1.3 1.9 ➄ ➄  ➃ 4.0  -
  V/VN 139    ➃  1.5 1.9 ➄ ➄  ➃  
  V/VN 161-212    ➃  2.5 1.9 ➄ ➄  ➃  
  V/VN 247    ➃  3.5 2.6 ➄ ➄  ➃  
  V/VN, PT/PTN 279    ➃  3.5 2.6 ➄ ➄  ➃  
  V/VN, PT/PTN 333    ➃  4.4 3.7 ➄ ➄  ➃ -  -
  V/VN, PT/PTN 385          
  V/VN, PT/PTN 500, 610          
  V, PT 952          
Explosion-proof
Totally Enclosed