Use and Care Manual

19
6-580.15
GENERAL PERFORMANCE DATA
Table 19.1 - Performance - Propeller (PDP)
jkl
Ratings shown are for elevations up to 2,000'. For elevations above 2,000', ratings should be reduced at the rate of 4%
for each 1,000' above sea level (in Canada see rating plate.) Reduction of ratings requires use of a high altitude kit.
Data taken at 55°F air temperature rise. At 65°F ambient and unit fired at full-rated input. Mounting height as measured
from bottom of unit, and without deflector hoods. For units equipped with deflector hoods, see page 23.
All motors used are produced, rated and tested by reputable manufacturers in accordance with NEMA standards and
carry the standard warranty of both the motor manufacturer and Modine. All motors are totally enclosed and all single
phase motors have built-in thermal overload protection.
Model Number
PDP 150 PDP 175 PDP200 PDP 250 PDP 300 PDP 350 PDP 400
Btu/Hr. Input
150,000 175,000 200,000 250,000 300,000 350,000 400,000
Btu/Hr. Output
124,500 145,250 166,000 207,500 249,000 290,500 332,000
Entering Airflow (CFM) 2180 2550 2870 3700 4460 4870 5440
CFM Range - - - - - - -
Air Temp. Rise (F) 51 51 52 50 50 53 54
Max. Mounting Hgt. (Ft.)
16 17 15 19 21 20 19
Heat Throw (Ft.)
@ Maximum Mgt. Height
55 59 51 67 74 70 69
Motor Type
PSC PSC PSC PSC PSC PSC PSC
HP
115/60/1 (PC01) 1/8 1/6 1/6 1/3 1/2 3/4 3/4
230/60/1 (PC02) 1/8 1/6 1/6 1/3 1/2 3/4 3/4
208/60/1 (PC03) N/A N/A N/A N/A N/A N/A N/A
Blower (BDP) Models
* See pages 20 and 21 for motor information
Model Number BDP150 BDP175 BDP200 BDP250 BDP300 BDP350 BDP400
Btu/Hr. Input 150,000 175,000 200,000 250,000 300,000 350,000 400,000
Btu/Hr. Output 123,000 143,500 164,000 205,000 246,000 287,000 328,000
Entering Airflow (CFM)
Low
CFM
Mid
CFM
High
CFM
Low
CFM
Mid
CFM
High
CFM
Low
CFM
Mid
CFM
High
CFM
Low
CFM
Mid
CFM
High
CFM
Low
CFM
Mid
CFM
High
CFM
Low
CFM
Mid
CFM
High
CFM
Low
CFM
Mid
CFM
High
CFM
1587 2020 2778 1852 2357 3241 2116 2694 3704 2646 3367 4630 3175 4040 5556 3704 4714 6481 4233 5387 6584
Max Mounting Height. (Ft.) 10 14 23 10 15 24 9 12 22 12 17 27 13 18 30 13 19 30 13 19 25
Air Temp. Rise (F) 70 55 40 70 55 40 70 55 40 70 55 40 70 55 40 70 55 40 70 55 45
Heat Throw (Ft.)
@ Max Mounting Height.
34 49 80 37 52 85 33 48 77 41 59 96 45 65 105 46 67 107 46 66 89
Heat Throw (Ft.)
@ 7’ Minimum Mounting Height.
45 71 120 49 76 128 43 68 115 57 87 145 64 97 160 66 99 164 66 99 136