OIL-FIRED, HORIZONTAL DELIVERY UNIT HEATERS
Modine model POR oil-fired unit heaters are built with time-tested and field-proven
components to provide optimum comfort and heating efficiency as high as 84%.
Standard features include:
• A long-life heat exchanger is made of corrosion-resistant, aluminized steel and roll-
formed to eliminate thermal stress. It contains a preformed, ceramic fiber fire-pot that
is lightweight, resilient, and resists both mechanical and thermal shocks.
• For ease of service, the heat exchanger is equipped with an inspection port,
two clean-out ports, and an amply-sized service door for removing fire pot when
replacement becomes necessary.
• A reliable, pressure-atomizing gun-type burner equipped with a stainless steel,
die-stamped flame-retention head that can increase combustion efficiency by as much
as 20 to 30 percent over non-flame retention-type burners.
• Beckett microprocessor-based ignition controller providing superior combustion and
safety monitoring.
• Onboard diagnostics with LED output for simplifying the lives of service personnel.
• Interrupted-duty ignition that disables the spark once ignition is proven. Older
technology uses a continuous spark that is noisy, prone to shorter lifespan, and not
energy efficient.
• Electronic oil igniter module with superior spark voltage (20kV) replaces traditional
bulky ignition transformers.
• Beckett CleanCut burner pump that uses a solenoid valve to instantly cut oil flow on
shutdown, eliminating soot formation from coasting stops.
• Two stage pump with PSC motor provides maximum fuel pressure delivery, even in
high lift applications.
• Finger-proof fan guard.
• The unit casing is treated for protection against corrosion prior to the application of
the attractive gray-green, baked-on polyester powder coat paint finish.
• Accessory Outside Combustion Air Kit converts the burner to accept outside
combustion air piping for tight building applications.
• Three Sizes • Pressure-Atomizing, Gun-Type Oil Burner • Cad-Cell Safety Shut-Off • Electric-Spark Ignition
• Fan and Limit Control
MODEL POR
Table 15.1 - Oil Fired Unit Heater Performance Data
➀ Deflector blades pitched 45° toward the floor. Mounting height is measured from floor to bottom of unit.
POR100 119,000 0.85 100,000 1890 460 49 12' 39'
POR145 175,000 1.25 145,000 2400 580 56 13.5' 50'
POR185 231,000 1.65 185,000 3200 740 54 12' 51'
Model Size
Input
Btu/Hr
Input
GPH
Output
Btu/Hr
CFM
@ 70°F
Delivery
FPM
Temp.
Rise (°F)
Max
Height ➀
Heat
Throw