Data Sheet

Page 6 ams Datasheet
Document Feedback [v1-01] 2015-Oct-12
AS-MLV-P2 − Detailed Description
Cross Sensitivities
Due to the basic operation principle of MOS gas sensors, the
AS-MLV-P2 sensor component does have a cross sensitivity to
humidity changes. This effect provides additional information
and widens the application range for the sensor. This feature
especially supports applications in environments where the
detection of significant humidity changes is supporting the
functionality, such as bathroom and kitchen environments.
Figure 7 shows the dependency of humidity using the example
of CO signals to get a visualized feeling for the effect. Please
note that this dataset is just meant to be an example and the
values may vary from sensor to sensor.
Figure 7:
Cross Sensitivity of Humidity for CO
Cross Sensitivity of Humidity for CO: Cross sensitivity of humidity for the example of CO. This data is just meant
to be a visualization of the influence of humidity and will vary slightly from sensor to sensor.
30 40 50 60 70 80
0,1
1
10
R
S
/R
0
% r.h.
30ppm CO