INSTALLATION INSTRUCTION
696 - LED Outdoor
WS-W69620
FIG.1
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screw (C1) and gasket (D1) from the mounting back plate.
4. Secure the mounting plate to the junction box using junction box screws (B1).The side of the mounting back plate marked GND must face
out.
CONNECTING THE WIRES (Fig. 2)
5. Connect the xture wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured. If your outlet box
has a green or bare copper ground wire, connect the xtures ground wire to it. Otherwise, connect the xture’s ground wire directly to the
back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
6. Place the xture on the mounting plate, and secure it with mounting screw (C1) and gasket (D1).
7. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the
outside of xture back plate where it meets the wall. Leave a space at the bottom to allow moisture to escape Fig. 3.
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig. 2 Wiring
Back Plate Dimensions
Junction Box
Caulking
Fig. 3 Sealing
D1
C1
B1
A1
Gasket
Mounting Screw
Junction Box Screw
Wire Connector
Ground Wire
Junction Box
Mounting Plate
Fixture
4 1/8”
4 1/8”
1 3/8”
1 3/4”
Ground Screw