Installation Sheet

Nov . 2019
INSTALLATION INSTRUCTIONS
WS-W57014 / WS-W57018
570 – Outdoor Wall Sconce
2
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement progr
am. Nov . 2019JANUARY, 2017
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Fig.1
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig. 2 Wiring
B
A
D
E
C
PREPARATION
MOUNTING THE FIXTURE (Fig. 1)
CONNECTING THE WIRES (Fig. 2)
COMPLETING THE INSTALLATION
1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.
2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts nece
3. Remove the mounting screw (B) and the rubber gasket (C) from the mounting back plate.
4. Drill holes in the wall aligned with the key holes in the mounting back plate, insert the plastic anchors (D)
5. Secure the mounting back plate to the junction box using standard junction box screws that comes with the junction box, fasten it to the
wall using wood screw (E).
Note: (i) using any other non-original-manufacturer provided junction box screw may result in safety issue;
(ii) The side of the mounting back plate marked “GND” must face out.
6. Connect the fixture’s wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a
green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directl y to the back plate
using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
7. Secure the fixture to the mounting back plate using the mounting screw (B) and the rubber gasket (C).
8. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the
outside of fixture back plate where it meets the wall. Leave a space at the bottom to allow moisture to escape Fig.3.
Junction Box
Caulking
Fig. 3 Sealing
Back Plate Dimensions
Mounting Back Plate
Wire Connector
Junction Box
Junction Box Screw
Plastic Anchor
Wood Screw
Mounting Screw
Rubber Gasket
Nov . 2019
WS-W57014 : 12 1/4”
WS-W57018 : 16 1/4”
WS-W57014 : 6”
WS-W57018 : 6 3/4”
1 3/4”
1 3/8”