Installation Sheet
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture, including the mounting hardware.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screws (D1) and gasket (E1), take down the plate glass.
4. Remove the mounting screws (C1) and take down the xture back plate.
5. Secure the mounting plate to the junction box using junction box screws (B1). The side of the mounting back plate marked
“GND” must face out.
CONNECTING THE WIRES (Fig. 2)
6. Connect the xture wire to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured. If your outlet box
has a green or bare copper ground wire, connect the xture’s ground wire to it. Otherwise, connect the xture’s ground wire directly to the
back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)
7. Secure the xture back plate to mounting plate with mounting screw (C1).
8. Secure the plate glass to the xture back plate with mounting screw (D1) and gasket (E1).
9. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the
outside of xture back plate where it meets the wall. Leave a space at the bottom to allow moisture to escape Fig. 3.
10. Place the metal frame with glass shade
on the xture back plate, and secure it
with mounting screw (F1).
Note: Caulk the screw using silicone for
wet location.
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig.2 Wiring
INSTALLATION INSTRUCTION
376 - Outdoor Wall Sconce
WS-W37622
FIG.1
Back Plate Dimensions
C1
A1
E1
D1
F1
B1
Mounting Screw
Wire Connector
Gasket
Mounting Screw
Mounting Screw
Metal Frame
Fixture Backplate
Junction Box Screw
Mounting Plate
Junction Box
Pressed Glass
Ø4”
1 1/8”
1 3/4”
Ground Wire
Plate Glass
Junction Box
Caulking
Fig.3 Sealing