Installation Sheet

2
INSTALLATION INSTRUCTIONS
201-Outdoor Sconce
WS-W20118
FIG. 1
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
FIG. 2 Wiring
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Aug. 2020
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
PREPARATION
1. Shut off the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area.
Be careful not to lose any small parts necessary for installation.
MOUNTING THE FIXTURE (Fig. 1)
3. Remove the mounting screw (B) and
Silicone Gasket (C)
from the xture.
4. Secure the mounting back plate to the junction box using standard junction box
screws that comes with the junction box.
Note: (i) Using any other non-original-manufacturer provided junction box screw
may result in safety issue;
(ii) The side of the mounting plate marked “GND” must face out.
5. Lay the front side of the xture on a clear area, insert the top and bottom
glass into the xture, the screw hole face up. Secure the glass to the xture
with hexagon socket screws (D) using the allen wrench (E) provided.
CONNECTING THE WIRES (Fig. 2)
6. Connect the xture’s input wires to junction box wires as shown in Fig. 2, make
sure that all wire connectors (A) are secured. If your outlet box has a green or
bare copper ground wire, connect the xture’s ground wire to it. Otherwise,
connect the xture’s ground wire directly to the back plate using the screw
provided. After wires are connected, tuck them carefully inside the junction box.
7. Secure the xture to the mounting back plate using the mounting screw (B) and silicone gesket (C) .
8. To prevent moisture from entering the outlet box and causing a short, use clear caulking(i.e. indoor/outdoor silicone sealant) to outline
the outside of xture back plate where it meets the wall. Leave a space at the bottom to allow the moisture to escape (Fig. 3).
B
A
Mounting Screw
Mounting BackPlate
Wire Connector
Junction Box
Ground Wire
Junction Box Screw
Allen Wrench
Silicone Gasket
Hexagon Socket Screw
Bottom Glass
Top Glass
(RPL-GLA-20118-02)
(RPL-GLA-20118-01)
E
C
D
Mounting Backplate Dimension
4
1
2
"
4
1
8
"
Ø2
3
4
"
Ø3
1
2
"
Caulking
Junction Box
Fig.3 Sealing