Installation Sheet

2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
197 - LED Outdoor
WS-W19770
Mounting Screw
Wire Connector
Junction Box Screw
Rubber Gasket
Allen Wrench
Allen Screw
Plastic
Anchor
Iron Studs
Wood Screw
Transformer
Back Plate Dimensions
Screw Tube
White Wire
Black Wire
Ground Wire
Mounting Plate
Junction Box
Black Wire
Red Wire
A1
B1
C1
D1
E1
F1
G1
H1
I1
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture,
including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear
area. Be careful not to lose any small parts necessary for installation.
CONNECTING THE WIRES (Fig. 2)
3. Remove the mounting screw (A1) and rubber gasket ( D1) from the
xture.
4. Secure mounting plate to the junction box using junction box screws
(C1), the side of the mounting plate marked “GND” must face out.
5. Drill a hole in the wall aligned with the screw tube located on the
xture tail, insert the plastic anchor (G1), fasten the wood screw (I1)
and the iron studs (H1) to the plastic anchor.
6. Connect the transformer input wires with junction box wires as shown
in Fig. 2, making sure that all wire connectors (A1) are secured.
If your outlet box has a green or bare copper ground wire, connect
the xture’s ground wire to it. Otherwise, connect the xture’s ground
wire directly to the mounting plate using the green screw provided.
After wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)
7. Place the xture over the mounting back plate and secure it with
mounting screws (C1) and rubber gasket ( F1).
8. Insert the screw tube to the iron studs, fasten it with Allen screw (F1)
using the Allen Wrench (E1).
9. To prevent moisture from entering the outlet box and causing a short,
use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the
outside of xture back plate where it meets the wall. Leave a space at
the bottom to allow moisture to escape Fig. 3.
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig. 2 Wiring
FIG. 1
Junction
Box
Caulking
Fig. 3 Sealing
5 3/4"
1 3/4"
4 1/8"
1 3/8"
2 7/8"