Installation Sheet
3
INSTALLATION INSTRUCTIONS
WS-68227/WS-68237
Phone (800) 526.2588
Fax (800) 526.2585
44 Harbor Park Drive
Port Washington, NY 11050
1600 Distribution Ct
Lithia Springs, GA 30122
1750 Archibald Avenue
Ontario, CA 91760
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
3000K3500K
2700K
MOUNT ON 4”X4” JUNCTION BOX
Fig.1 Mount on Junction Box
2
3. Remove the mounting screw (B) from the xture, and then take
down the mounting back plate.
4. The lamp can switch between three color temperatures
(2700K-3000K-3500K), which can be adjusted to your preference
with the switch in the canopy (Fig.4).
5. Drill holes in the wall aligned with the key holes located in the
mounting plate, insert the plastic anchors (G).
6. Secure the mounting ring (D) to the junction box using junction
box screws.The side of the mounting ring marked “GND” must face
out.
7. Secure the mounting back plate and conversion plate (E) to the
mounting ring(D) with the Assembly screws(C).
8. Secure the mounting plate to the junction box using Assembly
screws(C). Fasten the back plate to the wall with the plastic
anchors(G) and spacers(H) using the wood screws (F) provided.
9. Connect the xture’s wires to junction box wires as shown in Fig. 3,
making sure that all wire connectors (A) are secured. If your outlet
box has a green and bare copper ground wire, connect the xture’s
ground wire to it. Otherwise, connect the xture’ ground wire
directly to back plate using the GND screw provided. After wires are
connected, tuck them carefully inside the junction box.
10. Secure the xture to the mounting back plate using the mounting
screw(B).
Junction Box
Mounting Ring
Junction Box Screw
Assembly
Screw
D
C
Conversion Plate
Mounting Plate
E
Wood
Screw
Plastic Anchor
G
H
F
Spacer
Mounting Ring Dimensions
GN
D
1 3/4” 1 3/8”
φ4"
4 1/2”
1 3/8” 1 5/8”
6”
Conversion Plate Dimensions