1. Shut o the power at the circuit breaker and remove existing xture,
including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear
area. Be careful not to lose any small parts necessary for installation.
MOUNT ON 2”X4” SWITCH BOX
3. Remove the mounting screw (B) from the xture, and then take down
the mounting back plate.
4. The lamp can switch between three color temperatures
(2700K-3000K-3500K), which can be adjusted to your preference
with the switch in the canopy (Fig.4).
5. Drill holes in the wall aligned with the key holes located in the mount-
ing plate, insert the plastic anchors (H).
6. Secure the mounting plate to the switch box using Assembly screws(C).
Fasten the back plate to the wall with the plastic anchors(G) using the
wood screws (H) provided.
Note: (i) Using any other non-original-manufacturer provided
junction box screw may result in safety issue;
(ii) The side of the mounting plate marked “GND” must face out.
7. Connect the
xture’s
wires to junction box wires as shown in Fig. 3,
making sure that all wire connectors (A) are secured. If your outlet box
has a green and bare copper ground wire, connect the xture’s ground
wire to it. Otherwise, connect the xture’ ground wire directly to back
plate using the GND screw provided.
After wires are connected, tuck
them carefully inside the switch box.
8. Secure the xture to the mounting back plate using the mounting
screwS (B).
OR
Fig.1 Mount on Switch Box
Switch Box
3CCT
Switch
B
Mounting Screw
A
Wire Connector
Ground Wire
Mounting Plate
Assembly Screw
C
Wood
Screw
Plastic Anchor
F
G
WS-68227: 26 3/4”
WS-68237: 36 3/4”
1 3/8” 1 5/8”
WS-68227: 20 1/2”
WS-68237: 27 1/2”
2 3/4”