Installation Guide
Modern Forms
www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. DECEMBER, 2014 2
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig.2 Wiring
PREPARATION
- Shut o the power at the circuit breaker and remove existing xture, including the mounting hardware.
Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
MOUNTING THE FIXTURE (FIG. 1)
1. Remove the set screws (G1) from the xture, secure the crystal panel (F1) to the xture back plate (E1) using assembly screws (D1).
CONNECTING THE WIRES
2. Connect the xture wires to supply wires as shown in Fig.1, Fig. 2, making sure that all wire connectors (B1) are secured. If your outlet box
has a green or bare copper ground wire, connect the xture’s ground wire to it. Otherwise, connect the xture’s ground wire directly to the
mounting plate (C1) using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (FIG. 1)
3. Secure the mounting plate (C1) to the junction box (A1) using the junction box screws (I1).
The side of the mounting plate marked “GND” must face out.
4. Place the xture over the mounting plate (C1) and secure with set screws (G1).
INSTALLATION INSTRUCTION
Quantum - Vanity
WS-41512
Fig.1
I1
G1
B1
C1
D1
E1
F1
Junction Box
Screw
Set Screw
Supply Wires
Junction Box
Wire Connector
Assembly Screw
Mounting Plate
Fixture Back Plate
Crystal panel