Installation Sheet

Modern Forms
www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. SEPTEMBER, 2014
INSTALLATION INSTRUCTION
Glacier
WS-12721
100%-10% DIMMING
COMPATIBLE WITH THE FOLLOWING ELECTRONIC
LOW VOLTAGE (ELV) DIMMERS
Brand Model
LUTRON SELV-300P
LUTRON DVELV-300P
LEVITON MLE03-1
PREPARATION
1. Shut o the power at the circuit breaker and remove
existing xture, including the mounting hardware.
2. Carefully unpack your new xture and lay out the
parts on a clear area. Be careful not to lose any
small parts necessary for installation.
3. Remove the mounting screws (C1) from the xture.
4. Connect the xture wires to supplier wires as shown in
Fig. 2, making sure that all wire connectors (A1) secured.
Fixture and junction box ground wires should be connected
to mounting plate using green screw provided. After wires
are connected, tuck them carefully inside the junction box.
5. Secure the mounting plate (D1) to the junction box
(F1) using the junction box screws (B1). The side
of the mounting plate marked “GND” must face out.
6. Place the glass (E1) into the xture top. Secure it
using Allen screw (I1) and Allen wrench provided.
7. Place the xture back plate (G1) over the mounting
plate (D1) and secure with mounting screws (C1).
FIG.1
E1
I1
G1
C1
B1
D1
A1
F1
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig.2 Wiring
Fixture
Screw
Fixture
Mounting
Screw
Mounting
Plate
Wire
Connector
Junction
Box
Glass
Allen Screw